5.13 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
5.12 Max. time to wait until „0“ is displayed
(frequency meter)
This parameter indicates, how long it takes, when
measuring is active, until „0“ is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
6. Technical data
Supply voltage
AC power supply:
90 ... 260 V AC/max. 6 VA
DC power supply:
10 ... 30 V DC/max. 50 mA
with inverse-polarity protection
Display:
6 digits, red 7 segment
LED display, height 14 mm
Data retention:
EEPROM
Polarity of the inputs:
Programmable, npn or pnp
for all inputs
Input resistance:
appr. 5 k
Ω
10
5.8 Multiplying factor
(frequency meter)
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
5.9 Dividing factor
(frequency meter)
The decimal point defines
the resolution
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
5.10 Decimal point
(frequency meter)
5.11 Display mode
(frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min