EN - Page 5
4. If
YES is selected, press both keys simultaneously
to end the programming. The new values are
saved.
⇑
⇑
5. The device is ready for operation.
6. If, during operation, the operator switches to the
programming mode and alters the parameters
ou.Lo or ou.Hi take into account the following
when exiting the programming mode:
If the value of parameter
ou.Lo was altered, the
output of the device will automatically be set to the
value of parameter
ou.Lo when it will be set back
to operation.
If the value of parameter
ou.Hi was altered, the
output of the device will automatically be set to the
value of parameter
ou.Lo when it will be set back
to operation.
4.2.2 The MAn Operating Mode
1. The following parameters can be programmed for
the
MAn mode:
⇑
⇑
⇑
to
to
to
bei mA 24.00
bei mA 24.00
A
for mA 24.00
for mA 24.00
see page 6
2. Functions
–
Special display function, see 4.2.2.1
–
SiGnal allows selecting the setpoint output in volts
or mA.
–
output.Low allows defining the lowest output value.
–
output.High allows defining the highest output value.
–
StEP allows defining the increment. During operation,
the setpoint output will increase by this value when
the right key is pressed. The setpoint output will
decrease by this value when the left key is pressed.
During operation, it is not possible to define a value
lower than the
ou.Lo value or higher than the ou.Hi
value.
Note
If, during operation, the operator switches to the pro-
gramming mode and alters the value of
ou.Lo, ou.Hi,
di.Lo or di.Hi the parameter StEP will be reset to zero
and the output value will be reset to ou.Lo or di.Lo.
3. After setting the value of
StEP, press both keys
simultaneously; the following message is displayed:
4. Use the right key to select
YES or no
⇑
5. If
YES is selected, press both keys simultaneously
to end the programming. All parameters set are
saved.
⇑
⇑
6. The device is ready for operation.
4.2.2.1 The
to
to
to
bei mA 24.00
bei mA 24.00
A
SPecial disPlay Function in
MAn Operating Mode
1. If
YES was selected for
to
to
to
bei mA 24.00
bei mA 24.00
A
, the display
can show a value different from the value of the
output setpoint.