SKY PRO 1800 FORCED CIRCULATION MANUAL
C
C
23
Picture 3.11-4 Sketch of fixing flat roof system as a whole
ASSEMBLY LAYOUT FOR 2 SOLAR COLLECTORS
In the case of installation as series of 2 SKY PRO CPC 58 10, 12, 14, 16L, 18, 20, 22 solar collectors,
respect the distances indicated in the table 3.11-2 where P (width of ground fixing beams) is a fixed
measurement and B is variable (B is the distance between inside corner of 1st ground beam and the
following one: in case of 2 collectors you’ll have 3 fixing ground beams).
For more details, please refer to the manual assembly of the mounting system provided by the company,
within the kit box.
Table 3.11-2 : assembly measures concerning picture 3.10-4
MODEL
P [mm] B max [mm]
SKY PRO 10 CPC 58
60
700
SKY PRO 12 CPC 58
60
940
SKY PRO 14 CPC 58
60
1100
SKY PRO 16 CPC 58
60
1300
SKY PRO 18 CPC 58
60
1500
SKY PRO 20 CPC 58
60
1600
SKY PRO 22 CPC 58
60
1650
ASSEMBLY LAYOUT FOR 3 OR MORE SOLAR COLLECTORS
In the case of installation in series of 3 or more SKY PRO CPC 58 10, 12, 14, 16L, 18, 20, 22 solar
collectors, respect the distances indicated in the table 3.10-3 where P (width of ground fixing beams, see
picture 3.11-4) and C are fixed measurements (in case of 3 collectors you’ll need four triangular assembly
frames so the distance from the inside corner of 1st ground beam and 2nd one is B instead the distance
between the 2nd and 3rd is C, finally distance between the 3rd and 4th is again B), while B is variable and so
on.