SKY PRO 1800 FORCED CIRCULATION MANUAL
C
C
C
34
If more is needed solar surface will consist of multiple files in parallel, each with
same area, interconnected with the method TICHELMAN (pages 17 and 18 of this manual).
To design a system with non-standard dimensions and characteristics are necessary specific
calculations to determine pressure drop, diameter pipes, etc..
PUMP STATION FEATURES LOW - FLOW - flow 2-16 l / min
;
Technical data:
• Circulator pu
m
p: WILO RS
15/6;
• Measurement:
f
rom 2 to 16 l
/
min
;
• Minimum
w
ork temperature: - 20
°C;
• Ma
x
imum
w
ork
temperature:
+ 120°C
(
6 bar
) /
+ 100°C
(
10 bar
);
• Minimum room temperature:: +
4
0°C
;
•
Connections:
Ø 18 mm
compression
fittings
w
a
y ;
• Voltage: 230 V - 1 Ph -
5
0 Hz;
PUMP STATION FEATURES HIGH – FLOW - flow 15 : 42,5 l / min
Technical data:
• Circulator pu
m
p: GR
UND
FOS
UPS 25-80
1
80;
• Measurement:
f
rom 15 to
4
2,5 l/min;
• Minimum
w
ork temperature: - 20
°C;
• Ma
x
imum
w
ork
temperature:
+ 120°C
(
6 bar
) /
+ 100°C
(
10 bar
);
• Minimum room temperature:: +
4
0°C
;
•
Connections:
Ø
28
mm
compression
fittings
w
a
y ;
• Voltage: 230 V - 1 Ph -
5
0 Hz
;
LOW – FLOW
Nominal
power P
2
[W]
Velocity
(Rpm)
Adsorbed
Power P
1
[W]
Current at
1
̴ 230 V
WILO
RS 15/6
39
22
11
max
2550
2350
min
1900
67-
85
43
-
65
30
-
46
0,3
7
0,2
9
0,20