7  System requirements and license agreements 

7.1  System requirements 

The  program  is  a  32-bit-application,  which  is  driven  under  Windows  98,  Windows 
2000,  Windows  NT,  Windows  XP  or  Windows  7.  As  minimum  requirements  for  the 
adequate use the PC should show the following configuration: 
 

  Processor with pulse frequency from 1000 MHz or more 

  Hard disc with approx. 10..20 MByte free storage space 

  Graphic card with a minimum resolution of 800 x 600 points 

  Bluetooth ability to the connection of the external measuring hardware 

 

7.2  License agreements 

The  program  KTS  3D  as  well  as  the  entire  accompanied  electronic  or  printed 
documentation is subject to the copyright of KTS-Electronic Co. If parts of the present 
license  regulations  should  show  alterations  or  expansions  opposite  the  license 
regulations for former program versions they will come into force from the beginning 
of the day of entry. 
 

The present license regulations become effective on May 1

st

, 2007. 

 
Through  the  utilization  of  the  software  the  user  agrees  to  the  present  license 
regulations.  The  right  of  use  automatically  will  cease  if  the  license  regulations  are 
ignored. 

7.3  Utilization regulations 

After  full  payment  of  the  invoice  amount  the  customer  is  allowed  to  a  not-exclusive 
right of usage of the program listed in the bill. This right is restricted to the owner of 
the  original  software.  Consequently,  the  software  can  be  used  only  on  one  single 
computer system at the same time. All present and future copyrights and/or industrial 
protection  rights  of  the  provided  programs  and  of  all  programs  derivative  from  it, 
program modules or in this context produced records remain at KTS-Electronic. 

7.4  Liability exclusions 

The  present  program  was  tested  carefully,  nevertheless  mistakes  are  not  to  be 
excluded.  No  guarantee  is  adopted  for  the  usability  of  the  program  to  a  certain 
purpose.  Especially,  no  liability  is  adopted  for  consequential  damages  as  well  as 
profit and asset losses, that could result from the application of the program as well 
as the affiliated documentation. 
 
Prices may change without notice. The same applies to changes any sort in software 
or documentation. 

Содержание GPA 1000

Страница 1: ...Ground Penetrating Analyzer GPA 1000 User s Manual KTS 3 D KTS Electronic Germany ...

Страница 2: ... 1 Preadjustment 13 4 4 2 Start button 13 4 4 3 End of measurement 13 4 4 4 Transfer of measurement data 14 4 4 5 3 D figures 14 4 5 Search process measurements 14 4 5 1 Searches in counter direction 16 5 Program operations 17 5 1 Main window 17 5 1 1 Toolbar 17 5 1 2 Display range 18 5 2 Menu bar 18 5 2 1 Data menu 18 5 2 2 Display menu 18 5 2 3 Options menu 18 5 2 4 Info menu 18 5 3 Options wind...

Страница 3: ...absolutely or relatively 22 6 3 Accumulator and charger 22 7 System requirements and license agreements 23 7 1 System requirements 23 7 2 License agreements 23 7 3 Utilization regulations 23 7 4 Liability exclusions 23 8 Warranty 24 8 1 After expiration date 24 8 2 Legal note 24 9 Contact 25 ...

Страница 4: ...ctions can always be downloaded gratuitously from our website 1 2 Important details Please note Do not store appliance in wetness or high moistures Avoid current carrying overhead lines Do not use mobile phones during the operation Do not process any measurement during thunderstorms Accurate operation is not guaranteed with empty accumulator For the operation or loading please only use the compone...

Страница 5: ...iscrimination GOLD SCAN electronic unit with Bluetooth incl installed lithium ion accu with bag and carrying strap Powerful quick charger 2800 mAh with additional 110V adapter 45 cm 17 72 Ø search coil waterproof with carbon telescope pole grab handle Service English German French or Spanish user s manual 2 years manufacturer s warranty for the entire scope of delivery incl hardware and software ...

Страница 6: ...al and super probe Plug the bar into the mount of the probe Then insert the remaining parts in the correct order The universal or super probe can be attached to the holder now Afterwards the sensor cable must be connected Your device is now ready for use Fig 4 part demountable universal probe Fig Telescope bar Fig Telescope bar disassembled ...

Страница 7: ...and max 8 2 Volt SENSOR Display shows sensor values ECO Power save mode display lighting is off Toggle switch SENSOR CALIBRATION SENSOR Shows battery voltage BAT or current value sensor SENSOR or ECO CALIBRATION Shows calibration value Bluetooth connection is ready if green LED flashes and bound if LED lights up constantly Fig front of electronic unit GPA 1000 ...

Страница 8: ...current charge of battery switch on the electronic part with the turning knob to BAT This value must always lie over 7 5 Volt otherwise please charge the battery Then turn to the position SENSOR or ECO to read the sensor or calibration data on the screen The sensor data should always lie between 1 4 the calibration approx 2 5 before the calibration automatically is set it could temporarily show ot...

Страница 9: ...tooth connection to the main unit or if you have to reinstal Windows please copy the entire data content from the provided USB stick to the hard disc Additional software is not necessary Therefore your tool is operational and ready for use 3 2 Bluetooth pairing This menu item is completely preinstalled and only has relevance if software is not connected automatically with the GPA 1000 unit or you ...

Страница 10: ... Close button to conclude the procedure Click Start Computer System Properties Device Manager double click on Ports COM LPT Two subitems Standard Serial over Bluetooth link will appear you should memorize the lower COMPORT number After that open KTS 3D Software click on Options Serial Interface and choose the memorized COMPORT and click OK Restart the Software and the device will automactically co...

Страница 11: ...n Check the calibration over the toggle switch before searching approx 2 5 Now use this toggle switch when turning back to sensor position Assure yourself that the indicated value lies between 1 4 Should this not be the case change the search direction slightly so that the value stands between 1 4 The further search procedure is decribed under 4 3 4 2 Search with the super probe The super probe is...

Страница 12: ...d continue with the search 4 4 3D search mode For the exact examination of the ground the area should be divided into tracks These tracks can be scanned in the same direction or in counter direction The running direction is selectable in the settings window The track length can be selected variably during the search after large objects or excavations longer track lengths can be chosen For the sear...

Страница 13: ... By pressing the start button the search begins The results are shown on the screen 2 dimensionally while the measurements are completed automatically The start button must be pressed again at the next track 4 4 3 End of measurement After the last track has ended you are going to be questioned if you want to store the measurements With the O K button the measurement is stored internally on a place...

Страница 14: ...cation and its dimension 4 5 Search process measurements The GPA is a gauge which can measure alterations of ground anomalies caused by metal objects soil structure or excavations it also is able to discriminate from normal ground magnetism Correct results strongly depend on ground type and measuring method Areas to be measured should not have electric fields like high voltage cables or ground wir...

Страница 15: ...nto even tracks You may choose between 2 methods 4 5 1 Searches with rectification If you have chosen the search in rectification you should come back to the starting point after completion of each track and press the start button for the measurements of the second track ...

Страница 16: ...track step approx 1 Meter to the right and directly start the next track by pressing the start button For a precise measurement you should hold the search speed in a stable manner while you are walking the tracks This way objects can be detected at the same spot during counter direction For exact measurements track lengths between 5 to 10 Meters are advantageous ...

Страница 17: ...rts the display range is empty at first 5 1 1 Toolbar Some buttons are summarized for fast operation These are from left to right New shows a data reception with external hardware Start starts a data reception with a track Stop stops the data reception Live starts a data reception in live mode Open reads a stored file Save saves the current file Peak switches between absolute and relative ad Norm ...

Страница 18: ...with connected external measurement hardware A selection window appears for the adjustment of the measurement conditions Copy into clipboard copies the current view in the cache so that it can be inserted into every image editing application End ends program 5 2 2 Display menu In this menu you can switch between graphic and numeric views of measurements 5 2 3 Options menu The options menu entry op...

Страница 19: ...he path adjustment the index is defined for the data storage A selection dialogue appears after the search button is activated 5 3 2 Colors and coordinates Here you can choose colors for the coordinate ad graphic cursor and the background A color selection dialogue appears after activity of the corresponding buttons ...

Страница 20: ...ack length determines together with the values per track the distance step width between every individual measurement The number of values per track is limited to approx 100 The measurement begins after activating the Start button With the Cancel button program termination is possible anytime Furthermore one can switch between consensual and contrasensual movement The measurement can be released e...

Страница 21: ...ed nuance color like Of course the colors are dependent on the chosen adjustment A storage request appears at the end of the last track afterwards a switch to the three dimensional representation takes place 6 1 2 Display after completion of data recording The picture shown above appears from the before shown two dimensional representation ...

Страница 22: ...an switch between the absolute representation or a relative representation With the absolute representation the Z axis is expanded to the full available measuring range With the relative representation the value area is oriented by the smallest resp the largest measurement Thus a maximum detail resolution is reached this also has affection on the color representation 6 3 Accumulator and charger Th...

Страница 23: ... Through the utilization of the software the user agrees to the present license regulations The right of use automatically will cease if the license regulations are ignored 7 3 Utilization regulations After full payment of the invoice amount the customer is allowed to a not exclusive right of usage of the program listed in the bill This right is restricted to the owner of the original software Con...

Страница 24: ... handling gross carelessness or when repairs modifications additionally installed parts or extentions are carried out from persons which are not authorized on our part to do so Guarantee claims will neither effect an extention of the term nor they will implement a new time limit Further requirements in particular such through extraneous causes resulting damages are excluded unless a commitment is ...

Страница 25: ... 49 6105 911155 www KTS Electronic com email mail KTS Electronic com Office hours Mondays Thursdays 9 00 am to 16 30 pm Fridays 9 00 am to 16 00 pm Copyright KTS Electronic Mörfelden Walldorf Germany 2010 A duplication or usage of visual and textual content of this publication is not allowed without explicit consent ...

Отзывы: