4.4.1  Preadjustment 

With the "new" button on the screen the search begins, 
 

 
the  computer  requires  the  sensor  number,  track  length,  track  number,  track  and 
measurement speed, etc. 
 

 
 
4.4.2  Start-button 
By pressing the start button the search begins. The results are shown on the screen 
2-dimensionally,  while  the  measurements  are  completed  automatically.  The  start 
button must be pressed again at the next track. 
 
4.4.3  End of measurement   
After the last track has ended, you are going to be questioned if you want to store the 
measurements. With the O.K.-button the measurement is stored internally on a place 
intended for it. 
 
 

 

 

 

Содержание GPA 1000

Страница 1: ...Ground Penetrating Analyzer GPA 1000 User s Manual KTS 3 D KTS Electronic Germany ...

Страница 2: ... 1 Preadjustment 13 4 4 2 Start button 13 4 4 3 End of measurement 13 4 4 4 Transfer of measurement data 14 4 4 5 3 D figures 14 4 5 Search process measurements 14 4 5 1 Searches in counter direction 16 5 Program operations 17 5 1 Main window 17 5 1 1 Toolbar 17 5 1 2 Display range 18 5 2 Menu bar 18 5 2 1 Data menu 18 5 2 2 Display menu 18 5 2 3 Options menu 18 5 2 4 Info menu 18 5 3 Options wind...

Страница 3: ...absolutely or relatively 22 6 3 Accumulator and charger 22 7 System requirements and license agreements 23 7 1 System requirements 23 7 2 License agreements 23 7 3 Utilization regulations 23 7 4 Liability exclusions 23 8 Warranty 24 8 1 After expiration date 24 8 2 Legal note 24 9 Contact 25 ...

Страница 4: ...ctions can always be downloaded gratuitously from our website 1 2 Important details Please note Do not store appliance in wetness or high moistures Avoid current carrying overhead lines Do not use mobile phones during the operation Do not process any measurement during thunderstorms Accurate operation is not guaranteed with empty accumulator For the operation or loading please only use the compone...

Страница 5: ...iscrimination GOLD SCAN electronic unit with Bluetooth incl installed lithium ion accu with bag and carrying strap Powerful quick charger 2800 mAh with additional 110V adapter 45 cm 17 72 Ø search coil waterproof with carbon telescope pole grab handle Service English German French or Spanish user s manual 2 years manufacturer s warranty for the entire scope of delivery incl hardware and software ...

Страница 6: ...al and super probe Plug the bar into the mount of the probe Then insert the remaining parts in the correct order The universal or super probe can be attached to the holder now Afterwards the sensor cable must be connected Your device is now ready for use Fig 4 part demountable universal probe Fig Telescope bar Fig Telescope bar disassembled ...

Страница 7: ...and max 8 2 Volt SENSOR Display shows sensor values ECO Power save mode display lighting is off Toggle switch SENSOR CALIBRATION SENSOR Shows battery voltage BAT or current value sensor SENSOR or ECO CALIBRATION Shows calibration value Bluetooth connection is ready if green LED flashes and bound if LED lights up constantly Fig front of electronic unit GPA 1000 ...

Страница 8: ...current charge of battery switch on the electronic part with the turning knob to BAT This value must always lie over 7 5 Volt otherwise please charge the battery Then turn to the position SENSOR or ECO to read the sensor or calibration data on the screen The sensor data should always lie between 1 4 the calibration approx 2 5 before the calibration automatically is set it could temporarily show ot...

Страница 9: ...tooth connection to the main unit or if you have to reinstal Windows please copy the entire data content from the provided USB stick to the hard disc Additional software is not necessary Therefore your tool is operational and ready for use 3 2 Bluetooth pairing This menu item is completely preinstalled and only has relevance if software is not connected automatically with the GPA 1000 unit or you ...

Страница 10: ... Close button to conclude the procedure Click Start Computer System Properties Device Manager double click on Ports COM LPT Two subitems Standard Serial over Bluetooth link will appear you should memorize the lower COMPORT number After that open KTS 3D Software click on Options Serial Interface and choose the memorized COMPORT and click OK Restart the Software and the device will automactically co...

Страница 11: ...n Check the calibration over the toggle switch before searching approx 2 5 Now use this toggle switch when turning back to sensor position Assure yourself that the indicated value lies between 1 4 Should this not be the case change the search direction slightly so that the value stands between 1 4 The further search procedure is decribed under 4 3 4 2 Search with the super probe The super probe is...

Страница 12: ...d continue with the search 4 4 3D search mode For the exact examination of the ground the area should be divided into tracks These tracks can be scanned in the same direction or in counter direction The running direction is selectable in the settings window The track length can be selected variably during the search after large objects or excavations longer track lengths can be chosen For the sear...

Страница 13: ... By pressing the start button the search begins The results are shown on the screen 2 dimensionally while the measurements are completed automatically The start button must be pressed again at the next track 4 4 3 End of measurement After the last track has ended you are going to be questioned if you want to store the measurements With the O K button the measurement is stored internally on a place...

Страница 14: ...cation and its dimension 4 5 Search process measurements The GPA is a gauge which can measure alterations of ground anomalies caused by metal objects soil structure or excavations it also is able to discriminate from normal ground magnetism Correct results strongly depend on ground type and measuring method Areas to be measured should not have electric fields like high voltage cables or ground wir...

Страница 15: ...nto even tracks You may choose between 2 methods 4 5 1 Searches with rectification If you have chosen the search in rectification you should come back to the starting point after completion of each track and press the start button for the measurements of the second track ...

Страница 16: ...track step approx 1 Meter to the right and directly start the next track by pressing the start button For a precise measurement you should hold the search speed in a stable manner while you are walking the tracks This way objects can be detected at the same spot during counter direction For exact measurements track lengths between 5 to 10 Meters are advantageous ...

Страница 17: ...rts the display range is empty at first 5 1 1 Toolbar Some buttons are summarized for fast operation These are from left to right New shows a data reception with external hardware Start starts a data reception with a track Stop stops the data reception Live starts a data reception in live mode Open reads a stored file Save saves the current file Peak switches between absolute and relative ad Norm ...

Страница 18: ...with connected external measurement hardware A selection window appears for the adjustment of the measurement conditions Copy into clipboard copies the current view in the cache so that it can be inserted into every image editing application End ends program 5 2 2 Display menu In this menu you can switch between graphic and numeric views of measurements 5 2 3 Options menu The options menu entry op...

Страница 19: ...he path adjustment the index is defined for the data storage A selection dialogue appears after the search button is activated 5 3 2 Colors and coordinates Here you can choose colors for the coordinate ad graphic cursor and the background A color selection dialogue appears after activity of the corresponding buttons ...

Страница 20: ...ack length determines together with the values per track the distance step width between every individual measurement The number of values per track is limited to approx 100 The measurement begins after activating the Start button With the Cancel button program termination is possible anytime Furthermore one can switch between consensual and contrasensual movement The measurement can be released e...

Страница 21: ...ed nuance color like Of course the colors are dependent on the chosen adjustment A storage request appears at the end of the last track afterwards a switch to the three dimensional representation takes place 6 1 2 Display after completion of data recording The picture shown above appears from the before shown two dimensional representation ...

Страница 22: ...an switch between the absolute representation or a relative representation With the absolute representation the Z axis is expanded to the full available measuring range With the relative representation the value area is oriented by the smallest resp the largest measurement Thus a maximum detail resolution is reached this also has affection on the color representation 6 3 Accumulator and charger Th...

Страница 23: ... Through the utilization of the software the user agrees to the present license regulations The right of use automatically will cease if the license regulations are ignored 7 3 Utilization regulations After full payment of the invoice amount the customer is allowed to a not exclusive right of usage of the program listed in the bill This right is restricted to the owner of the original software Con...

Страница 24: ... handling gross carelessness or when repairs modifications additionally installed parts or extentions are carried out from persons which are not authorized on our part to do so Guarantee claims will neither effect an extention of the term nor they will implement a new time limit Further requirements in particular such through extraneous causes resulting damages are excluded unless a commitment is ...

Страница 25: ... 49 6105 911155 www KTS Electronic com email mail KTS Electronic com Office hours Mondays Thursdays 9 00 am to 16 30 pm Fridays 9 00 am to 16 00 pm Copyright KTS Electronic Mörfelden Walldorf Germany 2010 A duplication or usage of visual and textual content of this publication is not allowed without explicit consent ...

Отзывы: