5 Enclosure A 

Hints and instructions regarding the use in 

 hazardous areas 

 

5.7 Starting 

 
For covers with unlocked openings on the upper side no light metals may be used if the couplings are used as 
appliances of appliance group ll (if possible, from stainless steel). 
If the couplings are used in mining (appliance group l M2), the cover must not be made from light metal. In 
addition, it must be resistant to higher mechanical loads than if it is used as appliance of appliance group ll. 
 
The minimum distance “Sr” between the protection device and the rotating parts must at least correspond to the 
figures mentioned below. 
 
If the protection device is used as cover, regular openings complying with the explosion protection demands can 
be made that must not exceed the following dimensions: 
 

Openings 

Cover [mm] 

Top side 

Lateral parts 

Distance “Sr” 

Circular – max. diameter 

 10 

Rectangular – max. lateral length 

 10 

Straight or curved slot –  
max. lateral length/height 

prohibited 

 20 

 

 

C A U T I O N !  
If you note any irregularities at the coupling during operation, the drive unit must be turned 
off immediately. The cause of the breakdown must be found out with the table 
„Breakdowns“ and, if possible, be eliminated according to the proposals. The possible 
breakdowns mentioned can be hints only. To find out the cause all operating factors and 
machine components must be considered. 

 
Coupling layer: 

 

If coated (priming, painting etc.) couplings are used in hazardous areas, the requirements to 
conductability and layer thickness must be considered. In case of paintings up to 200 µm no 
electrostatic load can be expected. Multiple coatings that are thicker than 200 µm are prohibited 
for explosion group llC. 

 

5.8 Breakdowns, Causes and Elimination 

 
The below-mentioned errors can lead to an incorrect use of the RADEX

®

-NC coupling. In addition to the 

stipulations in these operating and mounting instructions please make sure to avoid these errors. 
The errors listed can only be clues to search for the errors. When searching for the error the adjacent 
components must be generally included. 
 

 

Due to incorrect use the coupling can become a source of ignition. 
EC Standard 94/9/EC requires a special care from the manufacturer and the user. 

 
General errors incorrect use: 

  Important data for the coupling selection was not forwarded. 

  The calculation of the shaft/hub connection was not considered. 

  Coupling parts with damage occurred during transport are assembled. 

  If the heated hubs are assembled, the permissible temperature is exceeded. 

  The fits of the parts to be assembled are not coordinated with each other. 

  Tightening torques are below/exceeded. 

  Components are exchanged by mistake/put together incorrectly. 

  A wrong or no laminae package is inserted into the coupling. 

 

Содержание RADEX-NC

Страница 1: ...ISO 16016 beachten Gezeichnet 23 05 12Kb Ersatz f r KTR N vom 26 03 09 Gepr ft 23 05 12 Kb Ersetzt durch RADEX NC Backlash free torsionally stiff and maintenance free steel laminae couplings type DK a...

Страница 2: ...2 Hints 2 1 Coupling Selection 2 2 General Hints 2 3 Safety and Advice Hints 2 4 General Hints to Danger 2 5 Proper Use 3 Storage 4 Assembly 4 1 Components of the Couplings 4 2 Hint regarding the Fini...

Страница 3: ...35 40 84 35 98 28 77 38 7 10 5 M10 49 42 55 104 40 116 36 91 48 11 10 5 M10 69 Table 2 Technicaldata RADEX NC size Technicaldata TKN Nm TK max Nm Max speed 1 min Torsional rigidity Nm rad Mass moment...

Страница 4: ...e selected in a way that the difference between the peak torque of the machine including all operation parameters and the frictionally engaged torque of the clamping ring hub is at least a service fac...

Страница 5: ...ire drive train is secured against unintentional engagement You can be seriously hurt by rotating parts Please make absolutely sure to read through and observe the following safety instructions All op...

Страница 6: ...best relative air humidity is under 65 4 Assembly The coupling is generally delivered in assembled contition Before assemby the coupling has to be controlled for completeness 4 1 Components of the Cou...

Страница 7: ...s and spare parts KTR does not assume any warranty claims resulting from insufficient refinish P R E C A U T I O N Any mechanical rework to couplings that are used in hazardous areas require an explic...

Страница 8: ...een fixed the EDK or s dimension can be adjusted by axial displacement of the hubs onto the shafts A T T E N T I O N Please make sure that the laminae packages are assembled as shown in illustration 6...

Страница 9: ...d the frictionally engaged torque of the clamping ring hub is at least a service factor of s 2 4 5 Displacements Alignment of the Couplings The values of displacement indicated in table 6 offer safety...

Страница 10: ...0 4 1 0 2 1 10 0 14 0 8 1 0 4 1 15 0 16 1 0 1 0 5 1 20 0 25 1 2 1 0 6 1 25 0 30 1 6 1 0 8 1 35 0 40 2 0 1 1 0 1 42 0 50 2 8 1 1 4 1 1 each laminae package Examples for the combinations of displacement...

Страница 11: ...ss II of category 2 and 3 coupling is not approved for device class 1 media class G gases fogs steams zone 1 and 2 coupling is not approved for zone 0 media class D dusts zone 21 and 22 coupling is no...

Страница 12: ...wear at the laminae package after this first inspection the further inspections can be effected in case of the same operating parameters respectively after 6 000 operating hours or after 18 months at...

Страница 13: ...ls For the applications in hazardous areas all screw connections have to be secured against self slackening additionally e g by glueing with Loctite medium tight illustration 11 RADEX NC C A U T I O N...

Страница 14: ...dous areas require an explicit release by KTR The orderer must send a drawing to KTR acc to which the manufacture must be made KTR checks this drawing and returns it to the orderer with approval 5 7 S...

Страница 15: ...the table Breakdowns and if possible be eliminated according to the proposals The possible breakdowns mentioned can be hints only To find out the cause all operating factors and machine components mus...

Страница 16: ...cro friction under the screw head and at the steel laminae package Danger of ignition due to hot surfaces 1 Put the unit out of operation 2 Check coupling parts and exchange damaged coupling parts 3 T...

Страница 17: ...steel laminae packages assemble coupling parts 5 Instruct and train the service staff Cracks in break of the steel laminae packages fixing screws Drive vibrations Danger of ignition due to sparking 1...

Страница 18: ...designed correspond to Article 1 3 b of Standard 94 9 EC and comply with the general Safety and Health Requirements according to enclosure II of Standard 94 9 EC The RADEX NC Servo laminae coupling i...

Отзывы: