NVT-E
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
42611 EN
19 of 27
4
Please observe protection
note ISO 16016.
Drawn:
2019-12-06 Pz/Bet
Replacing:
KTR-N dated 2019-02-14
Verified:
2019-12-06 Pz
Replaced by:
Testing the switching output can be started in the following menu:
Test for OUTX
Check Out X
C)ou_
Extenden functions
EF X
EF_
Settings OUTX
Out X
out _
n)oP - on
Parameter
____
►
►
►
Main menu meas. value
Meas. value
____
►
Testing options for the switching output
Options for setting from
to
/
/
/
:
Normal operation of
switching output
Switching off the switching
output permanently
Switching on the switching
output permanently
Options for setting from
to
Normal operation as a
frequency output
Output
frequency 1 Hz
Output
frequency 100 Hz
On completion of the tests make absolutely sure to set the function to normal operation
.
The switching status of the output is indicated by the LEDs in the display. The assignment of LEDs to the
switching output is shown in the table below:
Table 7:
Numbering of LED
Switching output x
Assignment with
2 switching outputs
Assignment with
4 switching outputs
1
LED 1 - yellow
LED 1 - yellow
2
LED 2 - red
LED 2 - red
3
LED 3 - yellow
4
LED 4 - red
In the factory settings the LED displays the physical condition of the PNP switching output
(switching output closed - LED is illuminated).
In some cases the logical function of the display is to act differently from the physical signal on the switching
output. Therefore, the display in this menu item can also be reverted
(switching output opened - LED is illuminated).
Example based on temperature:
Two switching outputs are available for temperature which are set as follows:
•
Upper switching contact: maximum contact, ascending make contact. The LED is illuminated when the
maximum value of temperature is exceeded and the temperature is beyond the requested range. Thus, the
status displayed is “error” if the LED is illuminated.
•
Lower switching contact: minimum contact, ascending break contact. The LED is illuminated with the factory
settings when the minimum value of temperature is exceeded. In this case the LED would be illuminated if the
status was in order.
4
Operation
4.7 Switching outputs
4.7.6 Testing the switching output
4.7.7 Changing display function of status LED