15 ELECTRICAL SYSTEM
104
The charging time may be longer at low temperatures.
This battery charger is not suitable for the trickle
charging of lithium-ion batteries.
Info
Never remove cover
1
.
–
Switch off the battery charger after charging and disconnect
from the battery.
Finishing work
–
Install the battery.
15.4
Changing the main fuse
Warning
Fire hazard
Incorrect fuses overload the electrical system.
–
Only use fuses with the required ampere value.
–
Do not bypass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle. It is located behind the battery.
Preparatory work
–
Turn the key in the ignition lock to the position
while the
engine is idling.
–
Raise the motorcycle with a lift stand. (
–
Fold the seat up. (
–
Remove the shock absorber.
E01025-10
Main work
–
Take off protection caps
1
.
E01026-10
–
Remove faulty main fuse
2
.
Info
You can recognize a faulty fuse by a burned-out fuse
wire
A
.
A spare fuse
3
is located in the starter relay.
–
Install a new main fuse.
Fuse (58011109120) (
–
Check that the electrical system is functioning properly.