14
ELECTRICAL SYSTEM
81
Preparatory work
–
Switch off all power consumers and switch off the engine.
–
Remove the seat. (
102224-10
Main work
–
Pull the starter relay
from the holder.
102225-10
–
Remove protection caps
.
–
Remove the faulty main fuse
.
Info
A defective fuse is indicated by a burned-out fuse wire
.
A spare fuse
is located in the starter relay.
–
Install a new main fuse.
Fuse (58011109110) (
–
Check that the electrical equipment is functioning.
Tip
Insert the spare fuse so that it is available if needed.
–
Mount the protection caps.
–
Mount the starter relay onto the holder and lay the cable.
Finishing work
–
Mount the seat. (