MK60SP 12/10/20 KEENAN FILTERS® by KTI Systems, Inc. www.keenanfilters.com
FIELD WIRING
(continued)
INTERFACE WIRING
4. Connect the KP300 control panel to the wiring harness and also the 12 VDC circuit protected power.
Inspect and recheck all connections, check that wire harness and connections are supported and
away from hot or moving equipment.
To
circuit protected
(circuit breaker
or fuse) 12 VDC
input
KP300 Panel
KH1010 Interface
To MK60SP/K60SP
filter
KP300 CONTROL
PANEL
CONNECTON
KH1010
INTERFACE
CONNECTION
1 YELLOW
CONNECTS TO
1 YELLOW
2 BLUE
CONNECTS TO
2 BLUE
3 GREEN
CONNECTS TO
3 GREEN
4 PURPLE
CONNECTS TO
4 PURPLE
5 GREY
CONNECTS TO
5 GREY
6 WHITE
CONNECTS TO
6 WHITE
7 BROWN
CONNECTS TO
7 BROWN
8 ORANGE
CONNECTS TO
8 YELLOW
CIRCUIT
PROTECTED
12 VOLT SUPPLY
KH1010
INTERFACE
CONNECTION
+12 RED
CONNECTS TO
+12
-12 BLACK
CONNECTS TO
-12
WIRE COLORS CAN BE INSTALLERS CHOICE
PAGE 12