100Mbps HDX:
selects fixed 100Mbps and half duplex
10Mbps FDX:
selects fixed 10Mbps and full duplex
10Mbps HDX:
selects fixed 10Mbps and half duplex
Flow Control – Current Rx Whether pause frames on the port are obeyed
Flow Control – Current Tx Whether pause frames on the port are transmitted
Flow Control – Configured Click to enable flow control for fixed speed settings.
When “
Auto
” Speed is selected for a port, this selection indicates the flow control
capability that is advertised to the link partner.
Maximum Frame
Enter the maximum frame size allowed for the switch port, including FCS.
The allowed range is
1518
bytes to
9600
bytes.
Excessive Collision Mode Configure port transmission collision behavior.
Discard
: Discard frame after 16 collisions (default).
Restart
: Restart back-off algorithm after 16 collisions.
Power Control
The column shows the current percentage of the power consumption per port.
The Configured column allows for changing the power savings mode parameters per
port.
Disabled
: All power savings mechanisms are disabled.
ActiPHY
: Link down power savings is enabled.
PerfectReach
: Link up power savings is enabled.
Enabled
: Both link up and link down power savings are enabled.
Save
Click to save the changes.
Reset
Click to undo any changes made locally and revert to previously saved values.
Refresh
Click to refresh the page. Any changes made locally will be undone.
-15-
Содержание KGS-2421
Страница 1: ...KGS 2421 KGS 1620 Web Management Interface User s Manual 1 DOC 110616 ...
Страница 61: ...2 8 MAC Table Screen of 24 Port Switch 61 ...
Страница 78: ...2 11 5 Wizard This handy wizard helps you set up a QCL quickly 78 ...
Страница 79: ...2 11 6 Wizard Port Policies Screen of 24 Port Switch Screen of 16 Port Switch 79 ...
Страница 97: ...3 3 Security 3 3 1 Network 97 ...
Страница 106: ...3 4 2 Port Status Screen of 24 Port Switch 106 ...