* Inflammable or explosive materials are prohibited to access the job site.
* Fumes and gases produced when welding are hazardous to health. Make sure to work in places 

where there are exhaust or ventilation facilities to keep fumes or emissions away from the 
breathing zone.

* Please remember to keep arc rays away from the other nearby people when welding. This is only 

due to the interference from arc rays.

* Never allow anybody else other than the operator himself to dislocate or modulate the welding 
machine.
* Welders have strong electromagnetism and frequency interference, so keep away people with heart 

pace or the articles which can be interfered by electromagnetism and frequency.

* The welding cable can not be pressed or stressed by apparatus, and the puckering angle can not be 

too small, otherwise the inside cable will be damaged which maybe result into accident.

* No touching on the output connection or any other electrification parts while welding.
* Do not use the welder to ice-out the pipelines. 
* Use forklift truck and stock to convey. Using Handles to lift is prohibited .
* Notice the rated duty cycle when welding. The overload using is prohibited. 

Safety Measures to be Taken to Assure the Correct Installation and Position

* Precaution must be taken to keep the operator and the machine from the foreign materials falling 

from up above. 

* The dust, acid and erodible dirt in the air at the job site can not exceed the amount required by the 

norm (excluding the emission from the welder).

* Inflammable or explosive materials are prohibited to access the job site. 
* The welder must be installed in the place where it can not be exposed to sun and rain. Also it must 

be stored in less humid place with the temperature range at -10~ 40°C.

* There should be 50cm space about for the welding machine to have good ventilation.
* Make sure that there is no metal-like foreign body to enter the welding machine.
* No violent vibration in the welder’s surrounding area.
* Make sure that there is no interference with the surrounding area at the installation site.
* Take measures to prevent wind while operating in the strong wind since the welder is gas shielded.
* If the welder is placed on the declining 10°plane , pay attention to dumpage .

Safety Check 

Each item listed below must be carefully checked before operation:

* Make sure that the welding machine has reliable earth connection.
* Make sure that there is always sound output and input wire connection instead of exposing it outside.

Regular check needs to be conducted by the qualified personnel after the welder has been installed 

over a period of six months, which involves as follows:

* Routine cleaning needs to be done to make sure that there is no abnormal condition happening in the 

tightened places such as the loose and slipped magnetic core, regulating screw, connecting wire 
happening in the welding machine.

* The external parts installed with the welder must guarantee that the welder works properly.
* Check the welding cable to see if it can continue to be used before it is worn out.
* Replace the welder’s input cable as soon as it is found to be broken or damaged.
* Make sure whether there is enough power supply to make the welding machine work properly.

Attention: Cut off the power supply before opening the case to check.

Содержание 410-PROTIG20

Страница 1: ...on 8 2 Safety Operation 2 Connection between Welder and Work Piece 8 Operator s Self protection 2 Connection between Welder and Torch 8 Attention 2 Connection between Welder and Electrode Holder 8 Saf...

Страница 2: ...overheating over lack voltage over current protection the power supply net compensation which boosts up along with the current decreasing is not less than 15 Anti jamming function of controlling syst...

Страница 3: ...ohibited to access the job site The welder must be installed in the place where it can not be exposed to sun and rain Also it must be stored in less humid place with the temperature range at 10 40 C T...

Страница 4: ...e frequency should not exceed 1 of the rated value The oscillation of the supplied voltage should not exceed 15 of the rated value Welder s Principle see following picture The 410 PROTIG20 welder appl...

Страница 5: ...ead gas input interface Open the casing can be seen on the body of the upper mounting plate with 1 piece of printed circuit board control floor is equipped with the main transformer coupling transform...

Страница 6: ...eff A Rated Virtual Input Current I2 Rated Welding Current U0 Rated No load Voltage U1 Rated Input Voltage U2 Conventional Load Voltage 50 60Hz AC Rated Frequency 50Hz Usable Frequency 60Hz V Conventi...

Страница 7: ...en Welder and Power Supply see input connection Input wiring diagram After welding machine panel of the power input line equipped with circuit breaker and grounding line access to the single phase 220...

Страница 8: ...socket on the front panel welding current very quick socket And tighten the clockwise grounding on the other end of the cable clamp work piece Connection between Welder and Torch see output connectio...

Страница 9: ...the screen to prevent others affected by the arc Operations shall not be placed near the site flammable items Welder each interface must be accurate and reliable connection Welding basic steps TIG we...

Страница 10: ...ple are allowed to be in charge of the repair job It is strongly recommended that customers contact our company for the technical back up or service when they feel unable to work out the technical hit...

Страница 11: ...k flowmeter and air pipe and recover the air supply Electropneumatic valve breaks down Exchange lectropneumatic valve Gas circuit blocks Exclude foreign body and dredge gas path 5 Non adjustable Elect...

Страница 12: ...t structure hold the handle or the bottom to move it The machines should be firmly fixed during the transportation The machines should be free from rain and snow Keep notice of Attention sign on the p...

Отзывы: