Schematic of Portable410-PROTIG20 Welding Machine

(Figure for reference, any update without notification)

9. Complete Set Specification

* Portable 410-PROTIG20 inverter DC arc welding 

machine

      1pcs  

*  Product Certificate

1pcs  

*  Operator’s Manual

1pcs  

Accessories and Consumable
*  Torch

1pcs  

*  Pottery nozzle (with one on the torch)

3pcs

*  Tungsten electrode holder (with one on the torch)

3pcs

*  Earth Cable

with earth clamp and quick connector

1pcs

  Remarks: a) No guarantee has been made yet to get the welding accessories repaired at any time 

because of its breakable attribute.

b) If there is any stipulation in the contract, then base on the contract.

10. Transport & Storage

* This series is chest structure, hold the handle or the bottom to move it. The machines should be firmly

fixed during the transportation.

* The machines should be free from rain and snow. Keep notice of Attention sign on the packing box. 

The storage ware should keep dry and air circulation & free from corrosive gas or dust. The tolerable 
temperature ranges from -25% to +55%, and the relative humidity can not be more than 90%.

* After the package has been opened, it is suggested to repack the product as per requirement for future 

storage and transport. (Cleaning job is required before storage and sealing the plastic bag for storage 
in the box.)

* Users should keep the packing materials with the machines to keep well storage during the long 

transportation. If the machines need transfer during the transportation, then wooden box is required. 
Sign such as ‘Lift’ and ‘Free of rain’ should be labeled on the box.

Содержание 410-PROTIG20

Страница 1: ...on 8 2 Safety Operation 2 Connection between Welder and Work Piece 8 Operator s Self protection 2 Connection between Welder and Torch 8 Attention 2 Connection between Welder and Electrode Holder 8 Saf...

Страница 2: ...overheating over lack voltage over current protection the power supply net compensation which boosts up along with the current decreasing is not less than 15 Anti jamming function of controlling syst...

Страница 3: ...ohibited to access the job site The welder must be installed in the place where it can not be exposed to sun and rain Also it must be stored in less humid place with the temperature range at 10 40 C T...

Страница 4: ...e frequency should not exceed 1 of the rated value The oscillation of the supplied voltage should not exceed 15 of the rated value Welder s Principle see following picture The 410 PROTIG20 welder appl...

Страница 5: ...ead gas input interface Open the casing can be seen on the body of the upper mounting plate with 1 piece of printed circuit board control floor is equipped with the main transformer coupling transform...

Страница 6: ...eff A Rated Virtual Input Current I2 Rated Welding Current U0 Rated No load Voltage U1 Rated Input Voltage U2 Conventional Load Voltage 50 60Hz AC Rated Frequency 50Hz Usable Frequency 60Hz V Conventi...

Страница 7: ...en Welder and Power Supply see input connection Input wiring diagram After welding machine panel of the power input line equipped with circuit breaker and grounding line access to the single phase 220...

Страница 8: ...socket on the front panel welding current very quick socket And tighten the clockwise grounding on the other end of the cable clamp work piece Connection between Welder and Torch see output connectio...

Страница 9: ...the screen to prevent others affected by the arc Operations shall not be placed near the site flammable items Welder each interface must be accurate and reliable connection Welding basic steps TIG we...

Страница 10: ...ple are allowed to be in charge of the repair job It is strongly recommended that customers contact our company for the technical back up or service when they feel unable to work out the technical hit...

Страница 11: ...k flowmeter and air pipe and recover the air supply Electropneumatic valve breaks down Exchange lectropneumatic valve Gas circuit blocks Exclude foreign body and dredge gas path 5 Non adjustable Elect...

Страница 12: ...t structure hold the handle or the bottom to move it The machines should be firmly fixed during the transportation The machines should be free from rain and snow Keep notice of Attention sign on the p...

Отзывы: