Installation and operating manual
KT-Elektronik
The following applies to the icon of the collector pump:
Symbol
Description
Icon off
Pump off
Icon flashes briefly
Condition to turn on the pump is met but the
pump is still off because of the minimum idle
time.
Icon is on but disappears for a
short time in intervals
Condition to turn off the pump is met but the
pump is still running because of the minimum
running time.
Icon on
Pump is running
1.4 Retrieving data - Information level
In the standard rotary switch position
„Information level“ one can retrieve
informations about time, date, as well as the temperature set-points for the connected
sensors and their current temperature.
Procedure:
Select value.
The screen now displays different items one after the other, depending on the
configuration of the controller.
__:__
Current time
Collector temperature CF
Temperature at storage sensor SF
Display the operating hours of solar circuit
Set-point/threshold and actual value comparison.
When the time is marked in the display, pressing the control button will show
the date.
8
EB_37381_SOL3-1_EN002
Note: Information can also be retrieved in level "manual operating mode". To do so,
select "Info", then confirm and proceed as described.