SOL3-1
10 Appendix
10.1 Function block lists
CO3: Solar circuit
F
Function
FS
Function block parameter description/value range (factory
default setting)
01
Forced pump
operation
0
CO3 F01 = 1 - Regular Forced pump operation active
chapter 4.1.6
02
Collector antifreeze
0
CO3 F02 = 1 - Antifreeze active
chapter 4.1.7
03
Start up function
(tube collector
function)
0
CO3 F03 = 1 - Start-up function active
chapter 4.1.5
F Function block number, FS factory setting, Sys System variant ID
CO5: system wide functions (all system variants)
If the controller signalizes CO5 -> F00 - 1, any access to return flow, volume flow rate and
performance settings is locked.
F
Function
FS
Function block parameter description/value range (factory
default setting)
01
02
03
Sensor initialization
1
0
0
Pt 1000
08 Summer time-/
Winter time-
switching
1
19 Temperature
monitoring
0
CO5 -> F19 - 1: Temperature monitoring active
20 Sensor calibration
1
CO5 -> F20 - 1: Setting all sensor calibration values
CO5 -> F20 - 0: Deleting sensor calibration values
21 Locking manual
operating mode
0
CO5 -> F21 - 1: In manual operating mode switch position
automatic operating mode is driven
22 Locking the rotary
switches
0
CO5 -> F22 - 1: rotary switch has no functionality
F Function block number, FS factory setting, Sys System variant ID
EB_37381_SOL3-1_EN002
41