9. Technical Data
Table 9.1 Technical Data
Model
KSG-10K KSG-12K KSG-15K KSG-17K KSG-20K
Input Data
Maximum power of PV
11KW
13KW
16KW
18KW
22KW
Maximum voltage of direct
current
1000V
Rated operational voltage
620V
Tracking scope of voltage
250V~950V
Full load MPP voltage
480V~800V
Maximum input current
13A/13A
21A/21A
DC switch
Standard configuration
Output data
Rated output power
10KW
12KW
15KW
17KW
20KW
Rated output current
15A
17A
22A
25A
29A
Rated alternating voltage
400Vac
Allowable voltage scope of
grid
320V~480V (Refer to Table 9-2/9-3)
Allowable frequency scope
of grid
50Hz ±2Hz (Refer to Table 9-2/9-3)
Power factor
0.8 lead / lag
THD of output current
<3%
Wired method
3W+N+PE / 3W+PE
Features
Maximum efficiency
98.0%
European efficiency
97.5%
97.7%
MPPT efficiency
99.9%
Standby loss
<2W
Cooling method
natural
Communication port
RS485 / WLAN/GPRS & Ethernet (Selectable)
Environmental
Available ambient
temperature
-25°C ~ +60°C
Humidity
0~95%, no condensation
Altitude
3000m
Noise
<
40dB
Protection level
IP65
Mechanical data
Dimension (W * H * D)
553*715*228mm
Weight
35.4Kg
45Kg
39.1Kg