Codes:

Depending from the Control Panel Model, up to 128 User Codes can be activated. In this Template, 5 
Codes have been already programmed as follows: 

1.

Nr. 1 MASTER CODE,

 

   default PIN: 147258

2.

Nr. 4 USER CODES

 

 , default PINs : 000003, 000004, 000005, 000006 

( which have to be activated 

either from the Master User Code or from the Installer Code

).

Tags:

Depending from the Control Panel Model, up to 128 Tags can be activated. In this Template, 5 Tags have 
been already programmed 

but need to be assigned from the Installer menu.

Voice Menu & Messages, SMS and WebServer (freely available with no license cost):

To take advantage of the Voice Menu and/or the SMS communication, the Control Panel needs to be 
linked to the 

gemino BUS 

Bi-Directional GSM/GPRS Communicator. 

Moreover, to take advantage from all 

fantastic remote WebServer capabilities,  it  is  necessary to adopt one of the Ksenia  Control Panel 
Models   with   integrates   the   IP   Connectivity

,   Ksenia   codes   :  

KSI1100016.300   -   KSI1100048.300   - 

KSI1100128.300

.

Even in this case, there is a Template Programming free downloadable from our web site in the RESERVED 
INSTALLER AREA : FILES DOWNLOAD => SOFTWARE => DEFAULT PROGRAMMING.
It is enough to download the programming file (default_en.zip), unzip and save it on a USB Key, connect 
the USB Key with the related Adapter (Ksenia code KSI7501000.020) to the Control Panel. From the 
Keypad, insert the Installer Code (123456), scroll the menu till ‘Program from USB’ and touch ‘ENTER’ . 
The upload may last a few minutes, at the end of them the CP has loaded all voice messages, SMS and 
WebServer.

The Control Panel is pre-programmed to send alarm events to the first 2 numbers of the Phone-Book as 
well as the SMSs to the numbers listed as 3 and 4. It will be enough to insert the phone numbers to 
activate this important feature of Alarm Signalling.

14

Содержание KSI1000016.300

Страница 1: ...trali integrate serie lares lares Integrated Control Panel Centrale int gr e serie lares CODICE INSTALLATORE DI FABBRICA 123456 CODICE UTENTE DI FABBRICA 147258 FACTORY DEFAULT INSTALLER CODE 123456 F...

Страница 2: ...L IMPIANTO 10 ENGLISH INTRODUCTION 12 DEFAULT PROGRAMMING DESCRIPTION 12 CONNECTION DIAGRAM 15 HOW TO ACTIVATE YOUR SYSTEM 17 HOW TO USE YOUR SYSTEM 19 FRAN AIS INTRODUCTION 21 DESCRIPTION DE LA PROGR...

Страница 3: ...to nel caso della programmazione di fabbrica ne sono definite tre 1 Disinserito entrambe le partizioni sono disinserite 2 Inserito entrambe le partizioni sono inserite con tempi di ingresso ed uscita...

Страница 4: ...di sabotaggio Pu essere utilizzata per collegare sirene di tipo universale o per attivare comunicatori esterni 2 Stato impianto una uscita logica che attiva i LED rossi lampeggianti sulla sirena da es...

Страница 5: ...gestione da remoto tramite web server e mappe grafiche necessario acquistare uno dei modelli di centrale che integrano a bordo la connettivit IP codici Ksenia KSI1100016 300 KSI1100048 300 KSI1100128...

Страница 6: ...ITALIANO SCHEMA DEI COLLEGAMENTI 6...

Страница 7: ...ro in parallelo con gli omonimi morsetti presenti in centrale I sensori devono essere collegati sui morsetti di ingresso ix o Mx con riferimento su negativo Nel caso di collegamento con configurazione...

Страница 8: ...la periferica al sistema 6 Ripetere la programmazione dal punto 4 fino a che tutte le periferiche non siano state assegnate compare sul display la scritta Nessuna periferica da assegnare 7 Una volta...

Страница 9: ...Scorrere il menu fino alla voce Gestione Chiavi e sfiorare il tasto Enter 4 Scorrere il menu fino alla voce Salva Chiavi e sfiorare due volte il tasto Enter 5 Avvicinare la chiave alla tastiera 6 Per...

Страница 10: ...odi Inserire il codice utente su tastiera ergo e digitare la cifra 2 Inserire il codice utente su tastiera ergo ruotare lo scroll fino alla visualizzazione della parola Modo Notte e sfiorare il tasto...

Страница 11: ...o dalla configurazione del sistema Chiedere all installatore del sistema le procedure da seguire Ksenia Security Srl declina ogni responsabilit nel caso in cui le apparecchiature vengano manomesse da...

Страница 12: ...odes have been already programmed as follows 1 Disarmed both Partitions are disarmed 2 Away both Partitions are armed with active entry and exit times mode full armed or away armed 3 Stay only the Per...

Страница 13: ...of Universal type or to activate external communication devices 2 Arming Status It is a logic Output which activates the flashing red LEDs on the Outdoor imago Siren when the system is armed Stay or A...

Страница 14: ...mote WebServer capabilities it is necessary to adopt one of the Ksenia Control Panel Models with integrates the IP Connectivity Ksenia codes KSI1100016 300 KSI1100048 300 KSI1100128 300 Even in this c...

Страница 15: ...ENGLISH CONNECTION DIAGRAM 15...

Страница 16: ...he homonymous terminals on the CP mother board The Detectors have to be connected on the Input terminals ix or Mx with reference to the negative In the case of a Double Balance configuration for the c...

Страница 17: ...ign it to your System 6 Repeat the programming sequence from step 4 to step 5 until all Peripherals will be assigned It will appear on the LCD Disaplay No peripheral to be assigned 7 Once the Assignin...

Страница 18: ...r two times 5 Approach your Tag close the Keypad logo Antenna area 6 To acquire more Tags repeat the sequence from step 4 7 Once the Enrolling Cycle is completed exit from the programming by touching...

Страница 19: ...t the User Code on the ergo Keypad and touch the number 2 2 Insert the User Code on the ergo Keypad and scroll up to Arm Stay and then touch Enter 3 Approach your Tag to the ergo Keypad and then repea...

Страница 20: ...tem configuration Please ask the system installer what procedures should be followed Ksenia Security srl waive any and all liability should the equipment be tampered with by unauthorized personnel The...

Страница 21: ...s Trois le sont dans la programmation par d faut 1 D sarm les deux partitions sont d sarm es 2 Arm mode absent les deux partitions sont arm es avec d lais d entr e et sortie actifs mode totalement arm...

Страница 22: ...sponibles directement sur la carte m re lares Elle dispose d un contact libre C NF NO et d un contact li directement 12 V R A Il se d clenche en cas de condition d alarme ou lorsqu un masquage est en...

Страница 23: ...et ou la communication SMS la centrale doit tre reli e au bus bidirectionnel du communicateur gemino GSM GPRS En outre pour profiter de toutes les fonctions distance du serveur web int gr il faut bien...

Страница 24: ...FRAN AIS SCHEMA DE RACCORDEMENT 24...

Страница 25: ...bornes homonymes sur la carte m re Les d tecteurs doivent tre connect s sur les bornes d entr e ix ou Mx avec une liaison la borne n gative Dans le cas d une configuration avec double r sistance de f...

Страница 26: ...c le num ro de s rie appropri appuyez Entr e deux fois pour l assigner votre syst me 6 R p tez les tapes 4 et 5 jusqu ce que tous les p riph riques soient assign s L cran LCD affichera Plus de p riph...

Страница 27: ...le code de l installateur par d faut 123456 sur le clavier ergo 2 Dans le menu faire d filer jusqu programmation et appuyez sur Entr e 3 Faites d filer le menu jusqu G rer les badges puis appuyez sur...

Страница 28: ...ieur volo et attendre que la couleur rouge apparaisse puis retirer le badge D sarmement Pour d sarmer votre syst me vous pouvez proc der en utilisant l une des m thodes suivantes Ins rez le code d uti...

Страница 29: ...tion WebServer Pour profiter de celle ci l utilisateur doit ouvrir un navigateur browser Internet et taper l adresse http lares_board du m me r seau o la centrale est connect Ce lien ne fonctionne que...

Страница 30: ...pendent de la configuration du syst me Demandez l installateur les proc dures du syst me suivre Ksenia Security Srl d cline toute responsabilit dans les cas o l quipement est alt r par des personnes...

Страница 31: ...ed with the following features to reduce its environmental impact Printed circuit laminates free of lead and bromine Low current consumption Packaging made mostly of recycled fibres and materials obta...

Отзывы: