ENGLISH
are meant to be utilized for windows and or curtain magnetic contacts.
3.
Zone from 7 to 10
. They have to be connected from the terminal 'M1' to the 'M4' of the CP. They
are all programmed with no delay, double-balance and belonging to the Partition “Volumetric
Detectors”. They are meant to be utilized for Volumetric Sensors installed inside the building.
Outputs:
Depending on the Control Panel Model, up to 128 Outputs can be managed contemporarily, linked to the
lares
Control Panel, the
ergo
Keypad
(up to 2 Zones per Keypad) and the
auxi
expansion modules (up to 5
Zones) all these being physical outputs OC (Open Collector) type. Additionally there are logic Ouputs,
which need to be used to activate events on the Bus Sirens (
imago
and
radius
). In this template 5 Outputs
have been already programmed as follows:
1.
Relay.
It is the only relay Output present on the Panel, whose terminals are available directly on
the
lares
Control Panel. It has a free contact (C-NC-NO) and one linked directly to +12V (+R, +A). It
activates itself when an alarm condition or a masking event is occurring. It can be used to link
Sirens of “Universal type” or to activate external communication devices.
2.
Arming Status
. It is a logic Output which activates the flashing red LEDs on the Outdoor
imago
Siren when the system is armed Stay or Away .
3.
Alarm imago
: it is a logic Output which activates the Outdoor
imago
Siren when a condition of
alarm or tamper are occurring.
4.
Alarm radius
: it is a logic Output which activates the Indoor
radius
Siren when a condition of alarm
or tamper are occurring and the System is Armed (AWAY).
5.
Manual Exit
: it is a physical Output, associated to the M1 Terminal of the Keypad
ergo.
It
activates / disactivates when the number 9 will be touched for more then 3 seconds on the
Keypad. It is meant to activate an external automation (automatic gate, door opening, garden
lights, etc.)
BUS Peripherals:
The Control Panel Architecture enables to configure many different Peripherals, whose number depends
from the CP model. In this template, 4 Peripherals have been already programmed as follows:
1.
Nr. 1
ergo
Keypad
(Ksenia code KSI2100000.300)
2.
Nr. 1
volo
Outdoor Proximity Reader
(Ksenia code KSI2200000.300Black or KSI2200000.310 in
White color)
3.
Nr. 1
r
adius
BUS
Indoor Siren with Emergency Light Function
(Ksenia code KSI6101000.300)
4.
Nr. 1
imago
BUS
Outdoor Siren
(Ksenia code KSI6301000.xxx with various color availability)
13