INTRODUCTION:
To allow you a quick installation, this
lares
Control Panel is available with a factory default programming
(template programming) with no need of a PC with the
basis
software, but simply using the system
Keypad.
Next paragraphs describe the Factory Configuration and the steps to be followed to install your panel in
the correct way.
DEFAULT PROGRAMMING DESCRIPTION:
Partitions:
The Partitions (or Areas) are a logic group of zones which can be armed or disarmed. Depending on the
Control Panel Model, up to 20 Partitions can be programmed. In this template, 2 Partitions have been
already programmed as follows:
1.
Perimetral Detectors
, meant for curtains, windows, doors and any detectors outside the building.
2.
Volumetric Detectors
, meant for the detectors inside the building.
Arm Modes:
They are used to arm/disarm Partitions. Depending on the Control Panel Model, up to 64 different Arm
Modes can be defined. In this template, 3 Arm Modes have been already programmed as follows:
1.
Disarmed:
both Partitions are disarmed.
2.
Away:
both Partitions are armed with active entry –and exit times (mode “full armed ” or “away
armed”.
3.
Stay
: only the “Perimetral Detectors” is armed ( mode “partially armed”). This is the most used
when one or more persons are at home, typically at night time.
Zones
:
The Zones are the Control Panel inputs, to be linked to the different detectors. Depending on the Control
Panel model, up to 128 Zones can be managed, linked to the
lares
Control Panel, the
ergo
Keypad
(up to 2
Zones per Keypad) and the
auxi
expansion
modules (up to 5 Zones each module). In this template 10
Zones have been already programmed as follows:
1.
Zone 1
. It has to be connected to the terminal 'i1' of the CP. It is programmed as “delayed” both in
entry and exit mode, NC (Normally Closed) and belonging to the “Perimetral Detectors“ Partition.
It is meant to be utilized for the magnetic contact at the main entrance.
2.
Zone from 2 to 6.
They have to be connected to the terminals from 'i2' to 'i6' of the CP. They are all
programmed with no delay, NC and belonging to the Partition called “Perimetral Detectors” . They