5 Installation at Site
24 of 96
Magnochem-Bloc
4. If required, install a filter in the piping (see figure: Filter in the piping).
1
2
Fig. 7:
Filter in the piping
1
Differential pressure gauge
2
Filter
NOTE
Use a filter with laid-in wire mesh (mesh width 0.5 mm, wire diameter 0.25 mm) of
corrosion-resistant material.
Use a filter with a filter area three times the cross-section of the piping.
Conical filters have proved suitable.
5. Connect the pump nozzles to the piping.
CAUTION
Aggressive flushing liquid and pickling agent
Damage to the pump!
▷
Match the cleaning operation mode and duration of flushing and pickling to
the casing materials and seal materials used.
5.4.1.1 Connecting an additional circulation line (only for vertical installation with
the motor on top)
For vertically installed pump sets, an additional external circulation line is required to
ensure correct priming and venting.
Fig. 8:
Layout of external circulation line
1
Shut-off element (suction side)
2
Shut-off element (external fluid
supply)
3
Shut-off element (discharge side)
4a/4b
Check valve
a
External circulation line
b
External fluid supply line