5
Installation at Site
5.1
Safety regulations
DANGER
Installation in potentially explosive atmospheres
Explosion hazard!
▷
Do not install the pump in potentially explosive atmospheres.
▷
Observe the information given in the data sheet and on the name plates of the
pump system.
5.2
Checks to be carried out prior to installation
Place of installation
WARNING
Installation on foundations which are unsecured and cannot support the load
Personal injury and damage to property!
▷
Make sure the foundation concrete is of sufficient strength (min. X0 to
DIN 1045).
▷
Only place the pump set on a foundation whose concrete has set firmly.
▷
Only place the pump set on a horizontal and level surface.
▷
Refer to the weights given in the general arrangement drawing.
CAUTION
Non-compliance with permissible cable bending radius
Damage to the cable!
▷
Observe the permissible minimum bending radius indicated in the
manufacturer's data sheet; consult KSB, if necessary.
1. Check structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
2. When selecting the place of installation make sure that connections 6B, 10E and
11E can easily be accessed during pump operation.
D00352
2
1
3
4
1
Connection 1M (pressure gauge) /
6D (vent connection, if required)
2
Connection 10E (barrier fluid) /
11E.3 (flushing liquid)
3
Connection 6B.4 (motor drain) /
11E (flushing liquid)
4
Connection 6B (casing drain)
5.3
Installing the pump set
The pump set can be installed in either horizontal position or vertical position (with
the motor on top or below).
Other installation types only after consultation with KSB.
5 Installation at Site
18 of 60
Etaseco/Etaseco I