1
Fig. 13: Pump set with shim
1
Shim
✓
The coupling guard and step guard, if any, have been removed.
1. Check the coupling alignment.
2. Unscrew the hexagon head bolts at the motor.
3. Insert shims underneath the motor feet until the difference in shaft centre height
has been compensated.
4. Re-tighten the hexagon head bolts.
5. Check that the coupling and shaft can easily be rotated by hand.
WARNING
Unprotected rotating coupling
Risk of injury by rotating shafts!
▷
Always operate the pump set with a coupling guard.
If the customer specifically requests not to include a coupling guard in KSB's
delivery, then the operator must supply one!
▷
Observe all relevant regulations for selecting a coupling guard.
DANGER
Risk of ignition by frictional sparks
Explosion hazard!
▷
Choose a coupling guard material that is non-sparking in the event of
mechanical contact (see DIN EN 13463-1).
6. Re-install the coupling guard and step guard, if any.
7. Check the distance between coupling and coupling guard.
The coupling guard must not touch the coupling.
5.8
Electrical connection
DANGER
Incorrect electrical installation
Explosion hazard!
▷
For electrical installation, also observe the requirements of IEC 60079-14.
▷
Always connect explosion-proof motors via a motor protection switch.
DANGER
Work on the pump set by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained electrician.
▷
Observe regulations IEC 30364 (DIN VDE 0100) and, for explosion-proof pump
sets, IEC 60079 (DIN VDE 0165).