4 Description
11 of 24
Controlmatic E.2
Protective functions
▪
The pump is protected against dry running by simultaneous monitoring of
pressure and flow rate. If there is a lack of water, the automatic control unit
stops the pump and the red signal lamp (7) is lit.
4.6 Technical data
Table 7:
Performance data
Characteristic
Value
Maximum operating pressure
10 bar
Maximum amperage
10 A
Fluid temperature
0 - +60 °C
Maximum flow rate
10 m
3
/h
Minimum flow rate
0,09 m
3
/h
Minimum start-up pressure
1,5 bar
4.7 Fluids handled
▪
Drinking water
▪
Service water
▪
Stormwater
▪
Fire-fighting water
▪
Cooling water
4.8 Displays and indicator lamps
Reset
Power
On
Failure
1
2
4
3
Fig. 3:
Indicator lamps
1
Ready for operation (green)
2
Fault (red)
3
Operation (yellow)
4
Reset button