6 Commissioning/Start-up/Shutdown
18 of 28
Cervomatic EDP.2
6.2.3 Pre-charging of accumulator
The accumulator is pre-charged to a pressure of 3.5 bar at the factory. The
accumulator should be pre-charged to a pressure of 0.2 bar below the pump start-up
pressure configured for dedicated pressure-dependent mode.
If pressure is insufficient:
▪
In manual mode, open a consumer installation and pre-charge the accumulator
via the valve using a bicycle pump and adapter.
▪
Screw the valve cap back onto the valve. Press AUTO On/Off.
6.3 Shutdown/storage/preservation
▪
Pull the pump plug.
▪
Remove the automatic control unit from the piping.
▪
Rinse off with clean water.
▪
Press in the check valve at the automatic control unit and shake water out of the
automatic control unit.
▪
Leave the automatic control unit to dry and store in a dry, dark and frost-proof
room.
▪
Special preservation measures are not required.
6.4 Returning to service
For returning the equipment to service, observe the items on commissioning/start-up.