SERVICING AFTER CLOGGING-UP OF GROUND COFFEE
Remove the cleaning inlet and the drawer.
Scrape and suck up the ground coffee in and around the thermoblock tank using a vacuum cleaner
with a small end piece (flexible hose with ~10 ext. diameter).
Carry out a cleaning cycle:
If the ejection ram works properly in the tank
Î
OK
If it sticks, activate manually with a rod inserted through the base:
Check that the drawer switch works properly: any ground coffee in the drawer slide channels could
affect the control. If this is the case, remove the technical mount to clean the slide channels.
Renew a cleaning cycle.
Determine the reason why clogging-up occurred (see troubleshooting diagnosis table):
grinder not compliant (quantity of ground coffee)
electronics setting not compliant with the grinder
ejection ram stuck in high position
cake tray replaced partially full
CLEANING AND SCALE REMOVAL CYCLES
The cleaning light comes on after 350 coffees (or espressos).
The scale removal light comes on after:
•
12,000 cycles with water hardness setting 0
•
10,000 cycles with water hardness setting 1
•
8,000 cycles with water hardness setting 2
•
6,000 cycles with water hardness setting 3
•
3,000 cycles with water hardness setting 4
with:
•
1 coffee (or espresso) = 1 cycle
•
1 "steam" function = 25 cycles (V16 picto power board and V6.8 to 7.0 Visu display)
= 40 cycles (V17 picto power board and V7.2 Visu display)
•
1 "hot water" function = 10 cycles
The number of cycles is doubled when a filter is used (progamming in the display version).