Distributor drain casing
Be careful to centre the spring properly on the bushing at the bottom of the drain body (risk that it
might catch on the notches).
The drain plunger must be mounted in the body of the drain with food grade grease.
Ensure that the drain body is firmly locked down on the distributor (tighten counterclockwise).
Electronic boards
Connectors on electronic boards: check that connectors are well secured by the clips.
Check the coffee volume selector button for correct indexation (1/2 turn possible error).
Check ground coffee cake thickness after any work on electronics or the grinder.
Steam nozzle
Be careful when replacing the O-ring as this is a delicate operation.
Body
There is a risk that switches might catch on the cake tray housing inside the body: press the body
down firmly when replacing.
9
Содержание XP7200 Series