Id.: 17-16-26-3017-03 | 6.2017
29
4.4.4 Condensate drainage
The device has one opening on the bottom side (WPL-45-K1 HT) or two openings (WPL-70-K1 HTT
and WPL-90-K1 HTT) for condensate drainage which is collected in the condensation vessel of the
device. The condensate accumulates on the evaporator from the air or is a consequence of evaporator
defrosting. The position of the drain(s) is shown on the pictures below (A).
WPL-45-K1 HT
WPL-70-K1 HTT and WPL-90-K1 HTT
A
A
The heating cable with thermostat is factory connected to the device. After connecting the condensate
pipe to the drains (A), the heating cable with thermostat must be inserted into it. The position of this
thermostat must be on the coolest part of the condensate pipe which leads into the drain. Turn the
thermostat which comes out the heating cable for 180° and insert it back into the pipe so that only 10
cm of the loop is sticking out.
Thermostat at the end of the heating cable.
10 cm leftover heating cable which you have to
insert back into the condensate pipe.