54
4.2 Technical data
Internal unit (HM)
HM-140 S1
HM-130 S1
HM-180 S1
External device
WPLV
–
09 S1
NT
WPLV
–
14 S1 NT
WPL-11-
S1 NT
WPL-13-
S1 HT
WPL-16-S2 NT
WPL-18-S2 HT
Version
Controller
TT3000 (MD1)
Device placement
Interior, wall
Electrical data
Internal unit
5)
1f connection
Electric heater
1 x 2 kW ~ 230 V
2 x 2 kW ~ 230 V
Frequency
Hz
50
Rated voltage
V
~ 230
Max. operational
current
A
11.8
20.6
Max. electrical
power
kW
2.6
4.6
Z
max
14)
Ω
/
/
Fuses
12)
A
1 x C16
1 x C25
Electrical power
cable
4)
mm
2
3 x 2.5
3 x 4
Internal unit
5)
3f connection
Frequency
Hz
50
Rated voltage
V
3N ~ 400
Max. operational
current
A
11.8
Max. electrical
power
kW
6.6
Fuses
12)
A
3 x C16
Electrical power
cable
4)
mm
2
5 x 2.5
Electric heater
3 x 2 kW ~ 230 V
Cooling system
Max. operational
pressure
MPa
5.0
2.9
Cooling (freon) line pipe connections
Pipe connection of
the liquid pipe
3/8''
Φ12
Pipe connection of
the gas pipe
5/8''
Φ22
Primary side (heat source) - air
Heating and cooling
Operating range -
min. / max. air
temperature
°C
Depending on the external air - water unit
Secondary side (heat sink) - water
Min. / Max.
pressure in the
system
MPa
0,1 / 0,3 (1,0 / 3.0 bar)
Recommended
dimensions of pipes
of the device
7)
DN
25
32
Heating
Rated flow
6)
m
3
/
h
1.0
1.4
1.8
2.1
2.7
3.0
Pressure drop at
rated flow
kPa
9
12
14
16
18
20
Range of operation
-
min. / max. water
temperature
°C
25 / 58
25 / 63
25 / 57
25 / 63
Cooling
Operating range -
min. / max. water
temperature
°C
7 / 25
Pipe connections for the water connection
Return line system
G1
’’
(ext. u.)
G5/4''
Supply pipe system
G1
’’
(ext. u.)
Содержание HM-130 S1
Страница 10: ...10 2 INSTRUCTIONS FOR THE END USER ...
Страница 13: ...13 ...
Страница 14: ...14 3 INSTRUCTIONS FOR THE INSTALLER ...
Страница 49: ...49 4 TECHNICAL CHARACTERISTICS ...
Страница 53: ...53 4 1 5 ELECTRICAL SCHEME Picture 27 Electrical scheme of the device ...
Страница 58: ...58 ...
Страница 59: ...59 ...