KRONE ISOBUS-Terminal CCI 100
69
Pos: 19.1 /Überschriften/Überschriften 1/K-O/KRONE ISOBUS-Terminal CCI @ 43\mod_1274786526625_78.doc @ 387485
8
KRONE ISOBUS-Terminal CCI 100
Pos: 19.2 /BA/Info-Center/CC-ISOBUS-Terminal/Im weiteren Verlauf Terminal auch als Bedieneinheit bezeichnet @ 46\mod_1281680416671_78.doc @ 445465
Note
In the operating instructions which follow, the terminal will also be referred to as the "control
unit".
Pos: 19.3 /BA/Sicherheit/Gefahrenhinweise/Bedieneinheit schützen @ 0\mod_1200308247867_78.doc @ 39598
Caution! - Protect Control Unit.
Effect: Damage to the control unit
•
The control unit must be protected against water.
•
If the machine is not used for an extended period of time (for example during the winter),
the control unit must be stored in a dry place.
•
For mounting and repair jobs, especially for welding jobs on the machine, disconnect the
power supply to the control unit. Overvoltage can damage the control unit.
Pos: 19.4 /BA/Info-Center/CC-ISOBUS-Terminal/CCI-Rundballenpressen/Allgemeine Beschreibung @ 50\mod_1287479272578_78.doc @ 470873
RPK50610_1
1
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F11
F12
ESC
CC000013
3
Fig.55
The electronic equipment of the machine consists essentially of the job computer (1), the
terminal (3) and the control and function elements.
The job computer (1) is located on the front left of the machine under the side hood.
Its functions are:
•
Control of the actuators installed on the machine
•
Sensor system/actuator diagnostics
• Bale
counter
•
Transfer of alarm messages
The control unit (3) communicates information to the driver and performs settings to operate the
machine. This information is received and further processed by the job computer.
Pos: 19.5 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165