4. 

Safety Aspects 

  It  is  inadmissible  to  use  fuels  other  than  specified  in heading  1. of  this manual.  In particular, it is 

forbidden to use such fuels as solvents or petrol 

  All activities regarding operation of thedevice must be performed in protective gloves and by a person 

trained for operation. 

  It is prohibited to put hands in the protective grids of the furnace or areas of the operating fan. 

  It is necessary to ensure efficient ventilation of the heated room in order to avoid carbon monoxide 

poisoning. 

  While cleaning the device or performing other maintenance activity, the device must be disconnected from 

power by removing the electrical plug from the power socket. 

  When connecting the device to a 240 vac GPO, it must be made sure that the wiring is operational and 

that it has differential current protection and earthing. 

The MTM 52 universal  oil  heater  is powered  by 240 vac, 50Hz.  It has two bimetallic sensors, ensuring safe and 
economic operation. The bimetallic sensor located on the heat exchanger closes a contact when the temperature 
exceeds 40°C and will open the contact when the temperature drops below 35°C. In emergency situations 
(overheating, oil overflow) the processor checks the bimetallic sensor signal and maintains  the  fan  operation until 
the furnace has cooled down to temperature below 35°C. 
The other bimetallic sensor is located on the heat exchanger as well and its threshold temperature equals 90°C. Its 
contact opening resulting from exceeding 90°C causes the  heater to immediately enter the Overheating phase (see 
point 8. in this Manual). The heater is also equipped with a weight sensor located under the combustion chamber (i.e. 
overflow cut-out).  When the tank of the cut-out has filled up, the heater automatically switches to the phase 
Overflow (see point 8. in this Manual). 

 

5.

 

Controller structure 

 

The connection  of the heater controlling panel to other system  components (sensors, pump, fan)  is factory-made. 
During normal use, due to safety, under no circumstances should there be any interference in the covered part of 
the  heater controller or duct integrity. Any action by an unauthorised person may result in electrocution (240V AC, 
50Hz) and burning. 

 

Fig. 1. The connection of the universal oil heater type MTM 52. 

Содержание Kozy MTM52

Страница 1: ...Kroll s Kozy Waste Oil Heater MTM52 Distributed and supported by Kroll Heaters Australia Sales Service ring 1800 805 243...

Страница 2: ...performance kW 30 Maximum heating performance kW 52 Minimum oil consumption kg h 2 5 Maximum oil consumption kg h 5 2 Heated air flow m3 5500 Power supply V Hz 240 50Hz Power intake W 300 Flue diamet...

Страница 3: ...contact when the temperature exceeds 40 C and will open the contact when the temperature drops below 35 C In emergency situations overheating oil overflow the processor checks the bimetallic sensor s...

Страница 4: ...sure stable draught inside the chamber during heater operation to provide optimal draught install an at least 5 metre long smooth vertical stack pipe resistant to high temperature not aluminium check...

Страница 5: ...lowing should apply pipe diameter 150 mm use the drop separator so that the condensate can leave the stack duct without damaging the pipe exchanger check the tightness of the flue sections minimal sta...

Страница 6: ...cooled down i e the fan has switched off and press the button on the casing of the bimetallic sensor Now pressing the Stop button will cause the Overheat led and the alarm to turn off The heater may...

Страница 7: ...Fig 6 The distribution of the heater safety components 1 Control thermostat and STB thermostat 2 Overflow cut out micro switch...

Страница 8: ...tire combustion chamber Check whether the furnace bowl is cool and clean and pour 500 ml of fuel or diesel oil Install the deflector Fire the oil up using paper crumbled into a ball set it on fire and...

Страница 9: ...e overflow bowl clean if necessary clean the combustion chamber base the element under the furnace bowl at least once a week check whether the air inlet openings in the lower and upper part of the com...

Страница 10: ...structed oil returns to the tank through the primary duct Clean the fuel duct and replace it if needed 6 The pump operation control thermostat has not reached proper temperature Wait until the furnace...

Страница 11: ...uirements EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN ISO 13732 1 2008 Ergonomics of the thermal environment Methods for the assessment of...

Страница 12: ...d on the market and does not cover component parts added by the end user or later actions performed by them This declaration expires if any changes are made to the device that have not been consulted...

Отзывы: