Kroll Kozy MTM52 Скачать руководство пользователя страница 2

 

 

Please do not use transformer oil as they can contain substances 

affecting operation and user health 

1.

 

Heater intended application and technical data 

 

The universal oil heater type  MTM  52  is designed to heat industrial  rooms  not  covered  with  central  heating  
systems  (workshops,  car  repair  shops,  industrial shops, warehouses, storage buildings, basements, garages, 
etc.). 

The heater can operate using most waste oils of mineral and plant origin, e.g.  engine,  gear,  hydraulic,  fuel  oil,  
with  maximal  density  in  temperature  of  15°C  equal to 860 kg/m3 and with ignition temperature exceeding 
56°C. 

 

  

 
TECHNICAL SPECIFICATIONS: 

 

MTM 52 

Minimum heating performance 

kW 

30 

Maximum heating performance 

kW 

52 

Minimum oil consumption 

kg/h 

2.5 

Maximum oil consumption 

kg/h 

5.2 

Heated air flow 

m3 

5500 

Power supply 

V/Hz 

240/50Hz 

Power intake 

300 

Flue diameter 

mm 

150 

Width cm 

60 

Height cm 

127 

Length cm 

120 

Weight kg 

120 

 

*

 

Calorific effect specified for fuel with the following parameters: 

 

calorific value = 42.6 MJ/kg. 

 

density at temp. max. 15°C = 860 kg/cm3. 

In case of higher parameters, the calorific effect can be increased even up to 55 kW. 

2. 

Environmental conditions 

The universal oil heater type MTM 52 must be stored in the following conditions: 

  temperature from -20°C to 85°C 

  relative humidity < 85% 

  pressure < 1200 hPa 

 dust 

free 

  environment free from chemical contamination. 

3. 

Conditions of Using 

  temperature from 0°C to 30°C 

  relative humidity < 85% 

  pressure < 1200 hPa 

  IP level IP21 

 Noise 

<70dB 

Содержание Kozy MTM52

Страница 1: ...Kroll s Kozy Waste Oil Heater MTM52 Distributed and supported by Kroll Heaters Australia Sales Service ring 1800 805 243...

Страница 2: ...performance kW 30 Maximum heating performance kW 52 Minimum oil consumption kg h 2 5 Maximum oil consumption kg h 5 2 Heated air flow m3 5500 Power supply V Hz 240 50Hz Power intake W 300 Flue diamet...

Страница 3: ...contact when the temperature exceeds 40 C and will open the contact when the temperature drops below 35 C In emergency situations overheating oil overflow the processor checks the bimetallic sensor s...

Страница 4: ...sure stable draught inside the chamber during heater operation to provide optimal draught install an at least 5 metre long smooth vertical stack pipe resistant to high temperature not aluminium check...

Страница 5: ...lowing should apply pipe diameter 150 mm use the drop separator so that the condensate can leave the stack duct without damaging the pipe exchanger check the tightness of the flue sections minimal sta...

Страница 6: ...cooled down i e the fan has switched off and press the button on the casing of the bimetallic sensor Now pressing the Stop button will cause the Overheat led and the alarm to turn off The heater may...

Страница 7: ...Fig 6 The distribution of the heater safety components 1 Control thermostat and STB thermostat 2 Overflow cut out micro switch...

Страница 8: ...tire combustion chamber Check whether the furnace bowl is cool and clean and pour 500 ml of fuel or diesel oil Install the deflector Fire the oil up using paper crumbled into a ball set it on fire and...

Страница 9: ...e overflow bowl clean if necessary clean the combustion chamber base the element under the furnace bowl at least once a week check whether the air inlet openings in the lower and upper part of the com...

Страница 10: ...structed oil returns to the tank through the primary duct Clean the fuel duct and replace it if needed 6 The pump operation control thermostat has not reached proper temperature Wait until the furnace...

Страница 11: ...uirements EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN ISO 13732 1 2008 Ergonomics of the thermal environment Methods for the assessment of...

Страница 12: ...d on the market and does not cover component parts added by the end user or later actions performed by them This declaration expires if any changes are made to the device that have not been consulted...

Отзывы: