6 Setup with the integrated display and adjustment unit
SU 600 • 4 … 20 mA signal conditioning instrument
30652-EN-150129
•
Set the function switch to position [
2
] (relay 1 off). Select the
value 10.0 (10.0 %) with the [
+/-
] keys. The internal relay 1 then
switches off when the value falls below this value. The respective
relay control lamp lights when the relay is energized. If the switch
-
ing points are too close together (< 0.1 %), the appropriate LED
flashes. The relay takes on the safe condition. In mode "
OPERATE
" an error message is outputted on the display.
•
If you want to control additional relays, proceed in the same way,
as with relay 1. The switch positions for setting the respective
relays are stated in the list of the function switch under "Setup
procedure".
Note:
If you want to change the mode (i.e. the switching function of the
relays), you have to exchange the On and Off values.