02/2019 - MA OPTIWAVE-M 7400 C R01 en
4
OPERATION
OPTIWAVE-M 7400 C
Measurement type
Description
Available units
Ullage volume
This is a display and an output function option. It
gives the empty volume that can be put in the tank.
This data is available if you prepare a volume table
in Program mode (Full Setup > Conversion).
m
³
, L, hL (hectolitre), in
³
, ft
³
,
gal (US gallons), ImpGal
(Imperial gallons), yd
³
, bbl
(oil), bbl (beer), custom
volume unit
Mass
This is a display and an output function option. It
gives the mass of the tank contents. This data is
available if you prepare a volume or mass table in
Program mode (Full Setup > Conversion).
kg, tn.l. (long ton), tn.sh. (short
ton), lb, t (tonne), Cst. Mass
(custom mass unit)
Ullage mass
This is a display and an output function option. It
gives the remaining mass that can be put in the
tank. This data is available if you prepare a volume
or mass table in Program mode (Full Setup >
Conversion).
kg, tn.l. (long ton), tn.sh. (short
ton), lb, t (tonne), Cst. Mass
(custom mass unit)
Reflection
This is a display and an output function option. It is
the percentage of the emitted radar signal which
makes a reflection on the surface of the liquid and
is received by the device.
%
Sensor value
This is a display and an output function option. It is
the distance from the face of the process
connection (flange face or thread stop) to the
surface of the liquid. You cannot change this value
in Program mode. Refer also to "Distance" in this
table.
m, cm, mm, in (inches), ft
(feet), custom length unit
4.3
Program mode
4.3.1
General notes
Change the settings of your device in Program Mode. Data about the menus is given on page 38. You
can:
•
Use the A Quick Setup menu to change the display language, change the tag name, log in to change
settings, do standard setup and empty spectrum recording procedures.
•
Use the B Test menu to run diagnostic tests, read measurement and spectrum data.
•
Use the C Full Setup menu to change settings. You can set up a conversion table for volume or mass
measurement, change current output values, change HART
®
settings, change how the
measurement data is shown in Normal mode, read device identification data, change critical
parameters for difficult process conditions, change the password, change measurement units or
reset the device to factory default settings.
CAUTION!
If you did not supply all installation data to the supplier before the delivery, the standard setup
procedure in the Quick Setup menu is mandatory.
INFORMATION!
It is not possible to enter the D Service menu. This menu is for factory calibration and approved personnel
only.