background image

 SAFETY INSTRUCTIONS 

1

3

OPTIFLUX 4000

www.krohne.com

10/2021 - 4003872405 - QS OPTIFLUX 4000 R08 en

Warnings and symbols used

HANDLING

•  

This symbol designates all instructions for actions to be carried out by the operator in the 

specified sequence.

i

RESULT

RESULT

RESULT

RESULT
This symbol refers to all important consequences of the previous actions.

Safety instructions for the operator

DANGER!

This information refers to the immediate danger when working with electricity.

DANGER!

These warnings must be observed without fail. Even partial disregard of this warning can lead to 
serious health problems and even death. There is also the risk of seriously damaging the device 
or parts of the operator's plant.

WARNING!

Disregarding this safety warning, even if only in part, poses the risk of serious health problems. 
There is also the risk of damaging the device or parts of the operator's plant.

CAUTION!

Disregarding these instructions can result in damage to the device or to parts of the operator's 
plant.

INFORMATION!

These instructions contain important information for the handling of the device.

CAUTION!

Installation, assembly, start-up and maintenance may only be performed by appropriately 
trained personnel. The regional occupational health and safety directives must always be 
observed.

LEGAL NOTICE!

The responsibility as to the suitability and intended use of this device rests solely with the user. 
The supplier assumes no responsibility in the event of improper use by the customer. Improper 
installation and operation may lead to loss of warranty. In addition, the "Terms and Conditions of 
Sale" apply which form the basis of the purchase contract.

INFORMATION!

Further information can be found in the manual, on the data sheet, in special manuals, 
certificates and on the manufacturer's website.

If you need to return the device to the manufacturer or supplier, please fill out the form 
contained in the manual and send it with the device. Unfortunately, the manufacturer cannot 
repair or inspect the device without the completed form.

Содержание OPTIFLUX 4000

Страница 1: ...X 4000 OPTIFLUX 4000 OPTIFLUX 4000 Quick Start Quick Start Quick Start Quick Start KROHNE 10 2021 4003872405 QS OPTIFLUX 4000 R08 en The documentation is only complete when used in combination with th...

Страница 2: ...conditions 9 2 8 1 Inlet and outlet 9 2 8 2 Bends in 2 or 3 dimensions 9 2 8 3 Bends 10 2 8 4 T section 11 2 8 5 Open discharge 11 2 8 6 Pump 11 2 8 7 Control valve 12 2 8 8 Air venting and vacuum for...

Страница 3: ...e instructions can result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation a...

Страница 4: ...nd to the local office of the manufacturer INFORMATION The remote version will arrive in two cartons One carton contains the signal converter and one carton contains the flow sensor Figure 2 1 Scope o...

Страница 5: ...the flow sensor Remote version electrical connection to the flow sensor via field current and signal cable INFORMATION Product specific information and extensive product specification is available usi...

Страница 6: ...nd in the documentation of the signal converter 1 Name and address of the manufacturer 2 Type designation of the flowmeter serial number manufacturing date and country of origin 3 Calibration data siz...

Страница 7: ...converter No special requirements Compact version Do not lift the device by the signal converter housing Do not use lifting chains To transport flange devices use lifting straps Wrap these around bot...

Страница 8: ...ct sunlight and install a sun shade if necessary Signal converters installed in control cabinets require adequate cooling e g by fan or heat exchanger Do not expose the signal converter to intense vib...

Страница 9: ...MATION Sensors of type VN02 up to DN10 the inlet and outlet sections are enclosed inside the sensor Figure 2 7 2 and or 3 dimensional bends upstream of the flowmeter 1 2 dimensions X Y 2 3 dimensions...

Страница 10: ...at the highest point will enlarge the risk of flowmeter malfunction because of air gas bubbles Vertical installation in combination with an open surcharge has to be avoided Vertical installation with...

Страница 11: ...on 1 t 10 DN Figure 2 11 Installation in front of an open discharge Figure 2 12 Installation behind a pump INFORMATION Recommended position to install a flowmeter is downstream a pump on a position wh...

Страница 12: ...front of a control valve INFORMATION Recommended position to install a flowmeter is upstream a control valve An electromagnetic flowmeter can be installed downstream of the control valve if there is n...

Страница 13: ...ion Install the flow sensor with the signal converter aligned upwards or downwards Install the flow sensor in line with the pipe axis Pipe flange faces must be parallel to each other CAUTION Max permi...

Страница 14: ...ot exceed the maximum torque value Step 1 Apply approx 50 of max torque given in table Step 2 Apply approx 80 of max torque given in table Step 3 Apply 100 of max torque given in table CAUTION Please...

Страница 15: ...68 47 68 200 PN 10 8 x M 20 84 84 68 68 50 200 PN 16 12 x M 20 68 68 45 45 250 PN 10 12 x M 20 78 78 65 65 48 250 PN 16 12 x M 24 116 116 78 78 300 PN 10 12 x M 20 88 88 76 76 59 300 PN 16 12 x M 24 1...

Страница 16: ...37 676 14 150 12 x 1 1835 1835 1538 1538 909 16 150 16 x 1 1767 1767 1481 1481 1141 18 150 16 x 1 1 8 2605 2605 2183 2183 1100 20 150 20 x 1 1 8 2365 2365 1984 1984 1618 24 150 20 x 1 1 4 3419 3419 28...

Страница 17: ...rd rubber Remote flow sensor 5 80 40 65 23 176 40 149 Compact with IFC 300 IFC 400 1 Compact with IFC 100 IFC 050 PU Remote flow sensor 5 65 40 65 23 149 40 149 Compact with IFC 300 IFC 400 1 Compact...

Страница 18: ...y please refer to the Ex documentation WARNING Observe without fail the local occupational health and safety regulations Any work done on the electrical components of the measuring device may only be...

Страница 19: ...12 t DN350 14 4 mm 0 16 Prevents damage to the flanges during transport and installation Especially for flow sensors with PTFE liner Grounding ring number 3 d DN300 12 3 mm 0 12 t DN350 14 4 mm 0 16 W...

Страница 20: ...Safety increases by reducing the number of potential leakage points The installation of the flowmeters is much easier Minimum requirements Size t DN10 3 8 Electrical conductivity t 200 S cm Signal cab...

Страница 21: ...t version with Compact version with IFC 300 IFC 300 IFC 300 IFC 300 a 155 mm 6 1 b 230 mm 9 1 1 c 260 mm 10 2 Total height H a Compact version with Compact version with Compact version with Compact ve...

Страница 22: ...mm 4 b 187 mm 7 36 1 c 270 mm 10 63 Total height H a Compact version with Compact version with Compact version with Compact version with IFC 050 10 IFC 050 10 IFC 050 10 IFC 050 10 a 100mm 4 b 157 mm...

Страница 23: ...185 9 80 40 200 200 209 200 12 100 16 250 250 237 220 15 125 16 250 250 266 250 19 150 16 300 300 300 285 27 200 10 350 350 361 340 34 250 10 400 450 408 395 48 300 10 500 500 458 445 58 350 10 500 5...

Страница 24: ...5 91 7 87 6 10 5 00 11 2 284 7 87 7 87 7 05 5 98 18 2 284 7 87 7 87 7 72 7 00 24 3 284 7 87 7 87 8 03 7 50 26 4 284 9 84 9 84 9 49 9 00 40 5 284 9 84 9 84 10 55 10 0 49 6 284 11 81 11 81 11 69 11 0 64...

Страница 25: ...0 1 741 5 91 7 87 5 71 4 87 11 1 741 7 87 7 87 6 65 6 13 13 2 741 9 84 7 87 7 32 6 50 22 3 741 9 84 7 87 8 43 8 25 31 4 741 11 81 9 84 10 00 10 0 44 6 741 12 60 11 81 12 44 12 5 73 8 741 15 75 13 78 1...

Страница 26: ...iner in PU Liner in PU Liner in PU DN200 1800 1500 500 600 Liner in Soft rubber Liner in Soft rubber Liner in Soft rubber Liner in Soft rubber DN50 600 40 1000 1000 Diameter Max pressure Vacuum load i...

Страница 27: ...NOTES 5 27 OPTIFLUX 4000 www krohne com 10 2021 4003872405 QS OPTIFLUX 4000 R08 en...

Страница 28: ...ng solutions Engineering commissioning calibration maintenance and training services Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 1038...

Отзывы: