Function and electrical data of the terminals:
Terminal
Function, electrical data
L, N
L+, L-
connection for mains, always non-EEx i
100..230 Vac, +10%/-15%, 22 VA
12..24 Vdc, +30%/-25%, 12 W
U
m
= 253 V
A, A-,A+
B, B-
C, C-
D, D-
Connection for signal in/outputs (PELV circuits),
non-EEx i or EEx i,
dependant on specific version of the IFC300-EEx
converter ordered. Consult the table with CG30 numbers
below for details
Table 5
Function and electrical data of the IFC300-EEx terminals
The exact IO-configuration for circuits A,B, C and D is order specific, that is
determined by the CG30 number shown on the converter, check sticker on the
backside of the IFC300 electronic unit.
The CG30 number contains 10 characters of which the last three (XYZ) determine
the IO configuration (IO circuits) :
CG30
*
*
*
X
Y
Z
pos 1.. 4
5
6
7
8
9
10
determine IO circuits
Table 6
Explanation to CG30 numbers
Schematic overviews of the CG30 numbers can be found in paragraph 2.2 (non-EEx i
IO in/outputs) and 2.3 (EEx i IO in/outputs).
The overviews do not show all details. The exact connection diagram for a specific
IFC300-EEx converter can be found on the sticker glued on the inside of the cover of
the connection compartment .
For use in gas hazardous areas:
The cable entry devices shall be in line with the type of protection chosen for the
terminal compartment, that is increased safety (EEx e) or flameproof enclosure
(EEx d). They should be suitable for the conditions of use and correctly installed.