Hazardous area supplement to the QuickStart
5 OPTIFLUX
OPTIFLUX 4000 DN 25 -150 (EEx qe coils, optional)
Temperature class
Max. process temperature Tp (in °C)
Ta
≤
40°C
40°C < Ta
≤
50°C
50°C< Ta
≤
60°C
T5 60
55 Not
possible
T4 110
105 100
T3 180
180 180
use heat resistant
cables for Tp above*
Not needed
155
105
OPTIFLUX 4000 DN 200 - 300 (EEx e coils, optional)
Temperature class
Max. process temperature Tp (in °C)
Ta
≤
40°C
40°C < Ta
≤
50°C
50°C< Ta
≤
60°C
T6 60
60 60
T5 80
75 75
T4 115
115 115
T3 160
150 140
use heat resistant
cables for Tp above*
Not needed
145
110
*The heat resistant cables must have a continuous operating temperature of at least 85°C.
•
The OPTIFLUX 4300 C is suitable for ambient temperature range of -40°C … +60°C.
•
The minimum process temperature for all DN sizes is -40°C. The process temperature limit (Tm) is determined by the
temperature class T6..T3 of the gas hazardous area of concern, the maximum ambient temperature (Ta), and the
nominal diameter.
•
For dust hazardous areas, the maximum surface temperature is equal to the medium temperature with a minimum of
85°C.
•
For ease of reference the flowmeter variants are simply denoted by main type of EEx-protection of the flow sensor,
e.g. EEx m for DN 10-20 range instead of the official EEx me.
OPTIFLUX 4300 C DN 10-20 (EEx m)
Temperature class (for gasses)
Maximum medium temperature ( in °C)
Ta
≤
40°C
40 < Ta
≤
50°C
50 < Ta
≤
60°C
T6
70 60
-
T5
95 85
60
T4
130 130
60
T3
150 150
60
OPTIFLUX 4300 C DN 25-150 (EEx d)
Temperature class (for gasses)
Maximum medium temperature ( in °C)
Ta
≤
40°C
40 < Ta
≤
50°C
50 < Ta
≤
60°C
T6
80 80
80
T5
95
95
80
T4
130
130
80
T3
150
150
80
OPTIFLUX 4300 C DN 25-150 (EEx q)
Temperature class (for gasses)
Maximum medium temperature ( in °C)
Ta
≤
40°C
40 < Ta
≤
50°C
50 < Ta
≤
60°C
T5
50
Not possible
Not possible
T4
100 95 80
T3
150 150
80
Содержание OPTIFLUX 4000 F
Страница 19: ...Hazardous area supplement to the QuickStart 15 OPTIFLUX Appendix 1 EC declaration of conformity ...
Страница 20: ...Altometer Addition to the Installation and Operating instructions Optiflux 4300 C EEx rev 0 20 07 2004 ...