DEVICE DESCRIPTION
10
OPTIBAR 5060
www.krohne.com
04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en
Category 2G (EPL Gb) equipment
OPTIBAR PC 5060, OPTIBAR PM 5060 with metallic-ceramic measuring cell
Category 2G (EPL Gb) equipment
OPTIBAR PM 5060 with piezoresistive or strain gauge measuring cell without cooling
fins
Category 2G (EPL Gb) equipment
OPTIBAR PM 5060 with piezoresistive or strain gauge measuring cell with cooling fins
If OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T are operated at temperatures higher than those
specified in the tables above, please make sure by means of appropriate measures that there is
no danger of ignition from the hot surface.
The maximum permissible temperature of the electronics/housing should not exceed the values
given in the tables above. The application conditions in areas without hazardous mixtures are
specified in the manufacturer information.
Temperature class
Ambient temperature range on
the electronics (zone 1)
Product temperature range
(sensor, zone 1)
T6
-50...+39°C / -58...+102.2°F
-50...+39°C / -58...+102.2°F
T5
-50...+70°C / -58...+158°F
-50...+100°C / -58...+212°F
T4
-50...+50°C / -58...+122°F
-50...+135°C / -58...+275°F
T3, T2, T1
-50...+50°C / -58...+122°F
-50...+200°C / -58...+392°F
Table 2-4: Application for category 2G equipment OPTIBAR PC 5060, OPTIBAR PM 5060 with metallic-ceramic
measuring cell
Temperature class
Ambient temperature range on
the electronics (zone 1)
Product temperature range
(sensor, zone 1)
T6
-50...+39°C / -58...+102.2°F
-50...+39°C / -58...+102.2°F
T5
-50...+70°C / -58...+158°F
-50...+85°C / -58...+185°F
T4
-50...+40°C / -58...+104°F
-50...+105°C / -58...+221°F
T3, T2, T1
-50...+30°C / -58...+86°F
-50...+120°C / -58...+248°F
Table 2-5: Application for category 2G equipment OPTIBAR PM 5060 with piezoresistive or strain gauge measuring cell
without cooling fins
Temperature class
Ambient temperature range on
the electronics (zone 1)
Product temperature range
(sensor, zone 1)
T6
-50...+39°C / -58...+102.2°F
-50...+39°C / -58...+102.2°F
T5
-50...+70°C / -58...+158°F
-50...+85°C / -58...+185°F
T4
-50...+50°C / -58...+122°F
-50...+120°C / -58...+248°F
T3, T2, T1
-50...+40°C / -58...+104°F
-50...+150°C / -58...+302°F
Table 2-6: Application for category 2G equipment OPTIBAR PM 5060 with piezoresistive or strain gauge measuring cell