KREMLIN REXSON
12
Manual : 574.331.112
BIMONTHLY PREVENTIVE MAINTENANCE
Check the tightening :
-
of the inlet valve on the body,
-
of the outlet valve or flange on the body.
Check there is no fluid leak coming from the piston of the proportioning part.
YEARLY PREVENTIVE MAINTENANCE
Remove, clean the inlet valve. Change the seals.
Remove, clean the outlet valve. Change the seals.
Remove, clean the proportiong part. Change the seals.
Check the piston.
Check the ball screw and the bearings.
When reassembling :
Lubricate the ball screw, the needle stop, the slides and the bearings (KLUBER
grease - STABUTHERM GH 461)
Lubricate the seals, the piston, the cylinder, the needle with PTFE MAGNALUBE
grease.
Nota : if using intensively the equipment, the maintenance frequency could be modified.
08. TROUBLESHOOTINGS
If a trouble occurs during the operating of the VOLUREX proportioning system, the fault will be displayed on the
bay display unit (refer to bay instruction manual).
09. DISASSEMBLY - ASSEMBLY
Guards (air motor cover, coupling shields, housings,…) have been designed for a safe
use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or damage to
property due to removal or partial removal of the guards.
DISASSEMBLY / ASSEMBLY OF THE COMPLETE PROPORTIONING SYSTEM
Disassembly :
Empty completely the proportioning system,
Shut off the air supply of the pump into operation,
Switch the 'AUTO-MANU' control box switch on 'MANU',
Drain the proportioning system,
Open the drain valve (pump or collector),
Switch off the proportioning system,
Disconnect the beads of the electric connection,
Remove the VOLUREX proportioning gun.
Assembly :
Install the new proportioning system,
Connect the fluid supply hose on the inlet valve,
Connect all the electric connectors,