06. INSTALLATION
PNEUMATIC CONNECTIONS
Install a HP fluid hose between the mastic regulator fluid outlet and the VOLUREX proportioning system
inlet valve. The hose can be a heated one to make easier the fluid flow.
Install an air hose (
4x6) to supply with compressed air the proportioning system. Connect it to the
compressed air network by means of a regulator.
ELECTRIC CONNECTIONS
Connect the electric cables between the control bay and the proportioning system.
Connect the interface electric cables between the control bay and the robot control box.
Connect the control bay to the network.
07. MAINTENANCE
Guards (air motor cover, coupling shields, housings,…) have been designed for a safe
use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or damage to
property due to removal or partial removal of the guards.
DAILY PREVENTIVE MAINTENANCE
Be certain the hoses are in good condition and that there is no leakage.
Drain the proportioning gun after a long duration shutdown.
Check the nozzle is clean and correctly tightened. Clean it or change it (clogging or bead fault).
MONTHLY PREVENTIVE MAINTENANCE
Check if there is air or fluid leakage at the inlet and outlet valves' level (fluid leakage detector).
Lubricate the ball screw (every 300
hours))
(KLUBER grease - P.N°. STABUTHERM GH 461)
(ball screw duration life : 500 000 cycles)
NEVER TAKE OFF THE BALL SCREW
FROM THE NUT.
Lubricate the needle stop
(KLUBER grease - P.N°. STABUTHERM GH 461)
2 lubricators (one located on the nut of the ball
screw, the other one located on the gear box)
enable to grease the ball screw as well as the
needle stop. Take off the carter to carry out the
lubrication.