![Krautzberger 200-0192 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/krautzberger/200-0192/200-0192_operating-instructions-manual_2003168031.webp)
WARNING!
Risk of injury due to improper cleaning!
Detergents may be harmful to one's health and be easily flammable. Furthermore, seals of the
diaphragm pump can be destroyed.
Note:
–
Adhere to the safety data sheets of the cleaning product manufacturer.
–
Do not fully immerse the valve housing in cleaning product.
–
Do not use any high-pressure cleaning devices.
9.
Clean the valve housing.
10.
Install all valve parts ( Fig. 9/3 to 4) in the sequence shown.
11.
Connect the pressure and suction connection ( Fig. 9/2).
12.
Fasten the screws ( Fig. 9/1) (
torque: 12 Nm
).
13.
Chapter 7.4 ‘Clean the diaphragm pump’ on page 29
) and
Chapter 6 ‘Operation’ on page 23
Diaphragm pump MP-560
ENGLISH
Article No. 200-0192