Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc
Order-No. 200-0157
4 Installation, mounting of the container
Pressure containers must be installed in such a way that:
neither employees nor third parties are at risk
they are accessible for regular inspection
the rating plate is easily visible
the pressure container can be operated from a safe and stable position
they are protected against external mechanical influences
they are protected against unauthorised access
4.1 Connections
Connect the material pressure hose leading to your extraction point to the material out-
let (4)
The material outlet can be located the bottom or routed through the container cover via a
riser pipe. The material outlet may have more than one port for the connection of more
than one consumer.
Connect the compressed air feed to the air connection (6)
The compressed air supply must be dry and oil-free. Make the necessary provision for a
suitable shutoff device (ball cock).
The compressed air fitting can be equipped with more than one (if necessary adjustable)
outlet for the connection of additional consumers (spray gun, stirrer etc.).
Connect the waste air line to the safety valve
Connect the earthing device and earth all conductive components in the working zone
Check firmness of all connections!
4.2 Filling
Each time before you fill the container:
Shut off the compressed air feed
Vent the container via the ball cock (8) until the container is pressureless
Switch off stirrer – if present
Do not open the container cover until the container has been fully vented!
There is increased risk of fire when you open the cover! In the working zone, avoid open
flames and red-hot components as well as equipment, tools and parts that can create ignit-
able sparks!
When removing the cover, make sure that the stirrer blades do not knock against the con-
tainer wall, thus creating ignitable sparks.
Loosen star-grip screws/clamp fasteners
Remove cover
5