Designation MDH
Type 50l
Dokumentation
DOK-315-GB.doc
Order-No. 200-0157
3
Before opening a pressure con-
tainer, the compressed air feed
must always be shut off and the
container rendered pressureless
via the venting valve!
Stirring mechanisms must be
switched off and secured against
accidental switch-on!
Rooms in which hazardous substances
are stored or processed must have
adequate ventilation. It may be neces-
sary to install a ventilation system.
If the ventilation system fails, work
must be stopped immediately and the
stirrer switched off.
Always comply with the relevant na-
tional and regional regulations.
Please always read and observe
the safety and treatment instruc-
tions of the material manufacturer –
in particular instructions relating
to:
the wearing of protective
equipment during the use
of hazardous substances
the avoidance of harmful or
explosive environments
Do not store any flammable sub-
stances, empty coating substance con-
tainers or other materials that have
been in contact with the coating sub-
stance (paper, cloths etc.) in the con-
tainer or in the working zone.
Do not use halogenated detergents.
Chemical reactions may cause explo-
sive and caustic compounds!
Electrostatic charges during opera-
tion of the pressure container can
lead to electric shocks and spark
formation.
The pressure container must there-
fore be earthed!
Air lines, material pipes and con-
tainers, equipment and electrically
conductive surfaces in the working
zones must also be earthed.
In the working zone, avoid open flames
and red-hot components as well as
equipment, tools and parts that can
create ignitable sparks.
Hang up “No Smoking” signs in a 5-
metre radius of the container. Make fire
extinguishers available if these are not
already in place!
Components connected by the op-
erator (hoses and pipes, fittings,
extraction devices etc.) must be re-
liably able to withstand the loads to
be expected during operation of the
pressure container (pressure, tem-
perature, chemical and mechanical
influences).
Before each operating step, check
hoses and pipes for possible dam-
age and ensure that they are firmly
connected. Loose, pressurised
hoses may cause accidents due to
whiplash-like movement and the
uncontrolled discharge of fluids.
Comply with all national and regional
water protection regulations!
Comply with all national and regional
waste disposal regulations!