8.11
Changing O-ring in the flat jet regulator
Disassembly
1.
Chapter 7.5 ‘Shutting down’ on page 24
).
2.
If necessary, secure fluid pressure pump or pressurised fluid container for the spray media
against restart.
3.
Interrupt the external material supply.
Fig. 23: Removing the O-ring
4.
Dismantle flat jet regulator ( Fig. 23/2) with a suitable fork wrench.
5.
Remove the O-ring ( Fig. 23/1).
Operating instructions
T-Dok-198-GB-Rev.3
[email protected], www.krautzberger.com
GB–44
Содержание 090-3566
Страница 60: ......