
42
User Menu items:
- Combustion Management
- Combustion Output
- Calibrate Auger
- Calibrate Fan
- Heating Management
- Heat Output
- Room Temperature
- Remote Control (this option is disabled for the VIKING pellet stove)
- CHRONO
- Mode
- Daily
- Weekly
- Weekend
- Schedule
- Daily
- Weekly
- Weekend
- Fill Auger
Table 4. User Menu
Item
Description
Combustion
Management
Moc
This feature modifies the combustion output. You can switch between Automatic
and Manual. In the Automatic mode, the controller will adjust the combustion
output to reach the temperature set on the thermostat. The letter A is displayed
at . In the Manual mode, the user can set one of the five levels. The letter M is
displayed at . The combustion output level is displayed with: :
Calibrate Auger
This modifies the speed setting of the pellet auger within ±10 % of each combu-
stion output level.
Calibrate Fan
This modifies the speed setting of the flue exhaust fan within ±10 % of each
combustion output level.
Heating
Management
Heat Output
This controls the heat output turbine speed to regulate the heating of the room.
You can switch between Automatic and Manual. In the Automatic mode, the con-
troller will adjust the heat output level to reach the temperature set on the ther-
mostat as soon as possible. The letter A is displayed at . In the Manual mode, the
user can set one of the five levels. The letter M is displayed at . The heat output
level is displayed with:
Room Temperature
This controls the room temperature set on the thermostat. You can set the tempe-
rature between 10 and 40 °C.
With the settings in the CHRONO Menu, you can schedule the operation of the
pellet stove for the whole week. First, enable one of the three modes available in
the menu. Next, set the times of automatic ignition and automatic turning off of
the pellet stove.
Содержание Viking 8
Страница 6: ...6 WYMIARY Rysunek 2 Wymiary ogrzewacza VIKING...
Страница 13: ...13 Rysunek 5 Zmiana pozycji kr ca dolotowego etap 1...
Страница 28: ...28 DIMENSIONS Fig 2 Dimensions of the VIKING...
Страница 35: ...35 Fig 5 Repositioning the air intake port Step 1...
Страница 49: ...49 ABMESSUNGEN Abbildung 2 Abmessungen des Raumheizers VIKING...
Страница 56: ...56 Abbildung 5 nderung der Position des Zuluftstutzens Schritt 1...
Страница 71: ...71 DIMENSIONS Figure 2 Dimensions du po le VIKING...
Страница 78: ...78 Figure 5 Modification de la position du raccord d entr e d air tape 1...
Страница 93: ...93 DIMENSIONI Dis 2 Dimensioni della stufa VIKING...
Страница 100: ...100 Dis 5 Modifica del posizionamento del tubo di giunzione di presa d aria fase 1...