31
INSTALLATION LOCATION
Specify the location in which the pellet stove will be installed. The pellet stove should be installed with
the air intake duct and the flue vent adapter duct featuring as few bends as possible. This will assure
the right chimney draught. The clearance to combustible walls and flammable materials around the
pellet stove shall be: 100 mm from the back, 300 mm from each side and a radius of 1000 mm from
the front glass. Never position the pellet stove near flammable materials, including wooden furniture,
carpets, rugs, or drapes/curtains. Do not leave clothes, towels, etc. to dry near the pellet stove, or the
may catch fire. The pellet stove shall sit on a firm and non-combustible base (floor).
Wybierając lokalizację dla ogrzewacza należy rozważyć kolejne punkty:
- The location of the room in the building the pellet stove is to be installed in
- The required minimum clearances from flammable materials
- Ventilation requirements
- The installation orientation and place
- The air ventilation system
- The general power outlet connection
Checks
- Controller
Table 2. List of the control system components of the VIKING pellet stove
CAUTION: This heating appliance is not compatible with concentric flue vent ducts!
Designation
Part number
Flow meter
PACCS11000001
Pellet sensor
PACCS10000001
Thermostat
0SEN1EL001304
Ceramic igniter
0RESRV000003
Encoder motor
0SER1AT000010
Encoder controller cable
0CABVCC000510
Flue exhaust fan
0VENATA000609
Air fan
0VENATA000602
Power cord
OPRE110000504
Power switch
PACCI16000403
Wire, white, H05V-K 1mm
PRZEWOD/H05V-K/BIALY
Wire, black, H05V-K 1mm
PRZEWOD/H05V-K/CZARNY
Wire, red, H05V-K 1mm
PRZEWOD/H05V-K/CZERWONY
Wire, blue, H05V-K 1mm
PRZEWOD/H05V-K/NIEBIESKI
Wire, yellow/green, H05V-K 1mm
PRZEWOD/H05V-K/ZOLTO-ZIELONY
Insulated bush, NCI 6.3-2.5/0.8 PVC
KONEKTOR/6,3/2,5/0,8
Igniter guard
PACC0000012
Содержание Viking 8
Страница 6: ...6 WYMIARY Rysunek 2 Wymiary ogrzewacza VIKING...
Страница 13: ...13 Rysunek 5 Zmiana pozycji kr ca dolotowego etap 1...
Страница 28: ...28 DIMENSIONS Fig 2 Dimensions of the VIKING...
Страница 35: ...35 Fig 5 Repositioning the air intake port Step 1...
Страница 49: ...49 ABMESSUNGEN Abbildung 2 Abmessungen des Raumheizers VIKING...
Страница 56: ...56 Abbildung 5 nderung der Position des Zuluftstutzens Schritt 1...
Страница 71: ...71 DIMENSIONS Figure 2 Dimensions du po le VIKING...
Страница 78: ...78 Figure 5 Modification de la position du raccord d entr e d air tape 1...
Страница 93: ...93 DIMENSIONI Dis 2 Dimensioni della stufa VIKING...
Страница 100: ...100 Dis 5 Modifica del posizionamento del tubo di giunzione di presa d aria fase 1...