Upgrading the Flash Memory
54
Note: If upgrading the firmware on more than one VS-1616A unit,
be sure to perform the above steps, 5 to 9, on each VS-1616A unit
before continuing
.
11. From your PC’s
K-Sender
program, click the
Send
button.
The color of the
Send
button changes to red and numbers appear
dynamically inside the blue line. The Displays on the
VS-1616A
show
the messages:
Transfer may take minutes
Please, wait…
Σ
=080756
1
12. Observe the PC monitor and the
VS-1616A MATRIX
and
STATUS
Displays. After about 30 seconds, the program installation completes, the
color of the
Send
button ceases to be red and the numbers inside the blue
line disappear. The Displays on the
VS-1616A
show the messages:
Program replaced
successfully!
Σ
=16608D
16608D
13. After about 3 seconds, the Displays show the messages:
Turn unit OFF, reconnect
cables and turn ON
Σ
=16608D
16608D
14.
Verify that the checksum (for example,
Σ
=16608D) is the same on
both lines
.
If not, repeat the firmware upgrade process from the beginning.
15. You have successfully replaced the previous program and upgraded to the
latest Kramer firmware version.
•
Turn the
VS-1616A POWER
switch OFF.
•
Reconnect the RS-232 IN and RS-232 OUT rear panel port
connections (as applicable).
•
Turn the
VS-1616A POWER
switch ON.
•
Observe the new version number that shows in the
STATUS
display.
•
Go to the Menu and restore your specific settings. Prepare
and store all necessary setups.
1 Shows the dynamic progress upgrade of the checksum