54
VP-773 - Port Tunneling
To setup and activate port tunneling on the
VP-773
:
1. Set the dedicated port tunneling Ethernet connection port type and port
number through which the
VP-773
will be passing RS-232 signals.
By default, the dedicated port settings are TCP, 5050.
To change these settings
see the “Port Tunneling Configuration” in the table
in
Section
12.4
.
2. Set the HDBT UART command (the table in
Section
12.4
).
By default, the settings are 9600,8,N,1
3. Make sure that the
VP-773
is connected to Ethernet.
The
VP-773
is now ready to tunnel RS-232 signals via Ethernet port tunneling.