Kramer Electronics Ltd.
VP-440X
– Technical Specifications
50
Default Communication Parameters
RS-232
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (route HDMI 2 to the output):
#ROUTE
1
,
1
,
2
<CR>
Ethernet
To reset the IP settings to the factory reset values go to: Menu->Setup -> Factory Reset-> press Enter to
confirm
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.254
TCP Port #:
80
Maximum TCP Ports:
1
Authentication
User/Password
Admin/Admin
Full Factory Reset
OSD
Go to: Menu-> Setup -> Factory Reset -> press Enter to confirm
Front panel buttons
Press the Reset to XGA/720p Button while plugging the power to reset the
machine
Input Resolution Support
Resolution/Refresh Rate
HDMI
PC
480I/576I
Yes
No
480P/576P
Yes
No
720P@(60/50)
Yes
No
1080I@(60/50)
Yes
No
1080P@(60/50)
Yes
No
1080P@(24/25/30)
Yes
No
640x480@(60/67/72/75/85)
Yes
Yes
800x600@(56/60/72/75)
Yes
Yes
1024x768@(60/70/75)
Yes
Yes
1280x1024@(60/75)
Yes
Yes
1280X960@60
Yes
Yes
1280X720@60
Yes
Yes
1920X1080@60
Yes
Yes
1600X1200@60
Yes
Yes
1280x768@60
Yes
Yes
1280x800@60
Yes
Yes
1360x768@60
Yes
Yes
1366x768@60
Yes
Yes
1400x1050@60
Yes
Yes
1600X900@60 RB
Yes
Yes
1680x1050@60
Yes
Yes
1920x1200@60 RB
Yes
Yes
2560x1400@60 RB
Yes
No
2560X1600@60 RB
Yes
No