Kramer Protocol
21
Examples:
Switch Video and Audio input 3 to output 7 #AV 3>7
CR
~AV 3>7 OK
CRLF
Switch Video input 2 to output 4
#V 2>4
CR
~VID 2>4 OK
CRLF
Switch Video input 4 to output 2 in
machine number 6
#6@VID 4>2
CR
~6@VID 4>2 OK
CRLF
Disconnect Video and Audio Output 4
#AV 0>4
CR
~AV 0>4 OK
CRLF
Switch Video Input 3 to All Outputs
#V 3>*
CR
~VID 3>* OK
CRLF
Chaining Multiple
commands*
#AV 1>* | V 3>4, 2>2, 82>1, 0>2 |V 82>3| A 0>1 | V? *
CR
First switch all Audio and video outputs from input 1,
Then switch video input 3 to output 4, video input 2 to output
2, video input and disconnect video output 2.
Then switch audio input 3 to output 2,
Then disconnect audio output 1.
Then get status of all links (assume this is 4x4 matrix).
Commands processing start after entering
CR
, response will sent
for each command after processing it.
~AV 1>* OK
CRLF
~VID 1>2, 3>4 OK
CRLF
~VID 82>3
ERR###
CRLF
~AUD 0>1 OK
CRLF
~V 1>1, 0>2, 1>3, 3>4
CRLF
Operation commands
Command
Syntax
Response
Lock front panel
LOCK-FP
LOCK-MODE
Short form: LCK
LOCK-MODE
LOCK-FP
LOCK-MODE RESULT
Get front panel locking state
LOCK-FP?
LOCK-FP
LOCK-MODE
Parameters Description:
LOCK-MODE =
Front panel locking state:
"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.
Restart device
RESET
RESET OK
Switch to protocol 2000*
P2000
P2000 OK
* Protocol 2000 has command to switch back to ASCII protocol (like protocol 3000)
Audio parameters commands
Command
Syntax
Response
Set audio level in specific
amplifier stage.
AUD-LVL
STAGE
,
CHANNEL
,
VOLUME
Short form:
ADL
STAGE
,
CHANNEL
,
VOLUME
AUD-LVL
STAGE
,
CHANNEL
,
VOLUME
RESULT
Read audio volume level AUD-LVL?
STAGE
,
CHANNEL
Short form: ADL?
STAGE
AUD-LVL
STAGE
,
CHANNEL
,
VOLUME
Mute audio
MUTE
MUTE-MODE
MUTE
MUTE-MODE
RESULT
Read audio mute state
MUTE?
MUTE
MUTE-MODE
Parameters Description:
STAGE
=
"In","Out"
or
Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for